OPERATION

Pre-Lighting Checklist

Be sure to check these items before the initial lighting of the insert:
c Gas pressure has been checked carefully - see Page 16.
c All gas fittings have been checked for leaks.
c All clearances to combustibles have been met-see Page 10.
c All combustible materials have been removed from the area
in front of the insert.
c All vented areas of the insert face are unobstructed.
c House is ventilated to clear initial paint curing odors - see Page
21.
c All packaging materials have been removed from the firebox.
c While appliance is cool, fingerprints or other marks have been
cleaned from any plated surfaces with denatured alcohol and a
soft cloth. Marks left on these surfaces may become permanent
into the finish if not removed prior to burning the unit.
c Firebox liner panels and glass media have been installed.
c The glass door is in place and is properly sealed.

Operating Instructions

See Page 31 for operating instructions.
IMPORTANT NOTE: When opening the lower door on the face
while the insert is burning, pull at the far left or far right
vent openings, because the door is hot during operation.
Intermittent/Standing Pilot Mode
(On/Auto Pilot Mode Switch)
This appliance can be switched from intermittent ignition to a standing pilot
simply by toggling the switch located in the lower control compartment
(refer to Figure 20). To save energy, switch to intermittent mode. To have
a standing pilot which will help startup during cold climate conditions by
warming the flue and the glass, switch to standing pilot.
The standing pilot mode is indicated by a pilot that comes on and remains
lit when the fireplace is off.
18
• Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. For assistance or additional
information, consult a qualified installer, service
agency or your gas supplier.
• Operation of this appliance when not connected
to a properly installed and maintained venting
system can result in carbon monoxide (CO)
poisoning and possible death.
• Carbon monoxide poisoning – early signs of
carbon monoxide poisoning resemble the flu
with headaches, dizziness, or nausea. If you
have these signs, get fresh air at once! Have
the heater inspected by a qualified service
technician. Some people are more affected by
carbon monoxide than others. These include
pregnant women, people with heart or lung
disease or anemia, those under the influence
of alcohol and those at high altitudes.
Electronic Gas Control Valve
SIT Proflame, Stepper
Figure 20
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
WARNING
Electronic Pilot
Assembly
O N
BU RN ER
TO TA L
RT
C O M FO
O L
C O N TR
AU TO
PI LO T
Unit-Mounted Controls