6.2

Programmable trigger switch

The configuration software (ScannerSetting_2D) provides a choice of three functions each for the fully depressed and
halfway positions of the trigger switch.
Scan:
The switch position turns on the marker beam and scans a code.
Marker: The switch position turns on the marker beam.
None:
The switch position does nothing.
Note, however, that the setting for the halfway position overrides the one for the fully depressed position if it has a
higher priority--that is, appears earlier in the above list. Specifying "Scan" for the halfway position and "Marker" for
the fully depressed position, for example, produces scanning for both positions.
6.3

Software control

You can control the scanner by sending scanning control commands from the host computer via the USB interface,
instead of pressing the trigger switch.
Scanning control commands include R, READON, LON, Z, READOFF and LOFF and are restricted by the trigger
switch operating modes, as listed below.
Commands
Ready-to-scan commands
R,
Upon receipt of one of these commands,
READON,
the scanner lights the illumination LEDs
LON
and becomes ready to scan.
Standby commands
Z,
Upon receipt of one of these commands,
READOFF,
the scanner turns off the illumination
LOFF
LEDs and switches to standby.
Each of these commands should be enclosed with a header and terminator for transmission according to the
communications conditions of the scanner.
Description
Trigger switch operating modes
Momentary
Auto-off
switching
mode
mode
--
--
--
--
22
(√ : Command valid)
Alternate
Continuous
switching
reading
mode
mode 1
--
--
Continuous
reading
mode 2