Extracting Ai (Application Identifier)-Prefixed Strings - Denso GT10Q-SU User Manual

2d code handy scanner
Hide thumbs Also See for GT10Q-SU:
Table of Contents

Advertisement

8.2.1.3 Extracting AI (Application Identifier)-prefixed strings

If the scanner reads an EAN-128, RSS, or EAN.UCC Composite symbol (excluding linear components in a
UPC/EAN Composite symbol), it edits the data according to AIs and outputs it in the data transmission format
selected in the scanner (see Chapter 10, Section 10.3).
The "AI-prefixed string" extraction is available in two modes--AI-delimited mode and AI parenthesizing mode. AIs to
be used for data editing are listed in (3) AI table later.
(1) AI-delimited mode
In this mode, the scanner extracts strings prefixed with AIs specified (up to three types of AIs) and separates them
with the specified delimiters (selectable from headers/terminators, commas and tabs) instead of AIs to output them.
Extraction conditions
Extraction conditions
"Data transfer regardless of error result"
If the scanner fails to extract an AI-prefixed string when the "Data transfer regardless of error result" is permitted, it
outputs the data read as is without editing.
Delimiters
Delimiters can be any of the following three--header/terminator, comma and tab.
• Header/terminator
Specifying a header/terminator as delimiters prefixes a header and suffixes a terminator to each element string
separated.
A prefix, suffix, the number of digits, and code ID mark can be also added to each element string if their
transmissions are enabled. The number of digits is the count of each element string edited.
Example Data read: (01)94901234567894(11)030808(13)030810
Code ID mark: Disable, Header: STX, Terminator: ETX,
Transmission of the number of digits: Enable, BCC: Disable, Prefix/Suffix: None
AIs specified
01,11,13
• Comma
Specifying a comma as delimiters outputs comma-delimited data. No comma follows the tail of the data.
A header and terminator are added to the full string. None of a prefix, suffix, the number of digits, and code ID
mark is added even if their transmissions are enabled.
Example Data read: (01)94901234567894(11)030808(13)030810
Code ID mark: Disable, Header: STX, Terminator: ETX,
Transmission of the number of digits: Disable, BCC: Disable, Prefix/Suffix: None
AIs specified
01,11,13
• Tab (ASCII 09H (HT))
Specifying a tab as delimiters outputs tab-delimited data. No tab follows the tail of the data.
A header and terminator are added to the full string. None of a prefix, suffix, the number of digits, and code ID
mark is added even if their transmissions are enabled.
Example Data read: (01)94901234567894(11)030808(13)030810
Code ID mark: Disable, Header: STX, Terminator: ETX,
Transmission of the number of digits: Disable, BCC: Disable, Prefix/Suffix: None
AIs specified
01,11,13
Permit/Prohibit
[STX]001494901234567894[ETX][STX]0006030808[ETX][STX]0006030810[ETX]
[STX]94901234567894,030808,030810[ETX]
[STX]94901234567894[TAB]030808[TAB]030810[ETX]
Choices
Output data
Output data
Output data
33