INSTALLATION OF SOLAR COLLECTORS

COLLECTOR FITTINGS INSTALLATIONS

Connect the fittings to the collectors as shown in the diagrams below:
STOP END
1/2" TO 3/4"
UNION
COLD FLOW
PIPE SUPPLIED
BY INSTALLER
When connecting collectors to other
collectors or to other copper pipe
with compression unions, ensure
that the compression union is held
in two points as shown in the picture.
One side should be held still
while the other side is tightened.
Not doing this can cause damage
to the collector.
Figure 29 - Collector Fitting Details (Enduro, Equinox & Excelsior Collectors)
Rinnai Australia
COMPRESSION
UNION
COMPRESSION
UNION
- 28 -
Solar Split Systems Operating / Installation Manual Version 8 - 18/10/10
AIR BLEED
VALVE
HOT SENSOR
HOT
SHEATH
SENSOR
LEAD
1/2" NUT
RETURN PIPE
SUPPLIED BY
1/2" OLIVE
INSTALLER
STOP END