Specifications For Solar Collectors - Rinnai PRESTIGE Operation & Installation Manual

Solar split systems
Table of Contents

Advertisement

SPECIFICATIONS FOR SOLAR COLLECTORS

Table 3 - Model Numbers and Specifications
CHARACTERISTICS
TYPE
CONSTRUCTION
- Waterways
- Absorber
- Selective Surface
Maximum Operating
Pressure
Casing Material
Overall Dimensions
(L x W x H) (mm)
Weight empty
(STD/FTC) (kg).
Water volume (Litres)
Number risers
Potential Solar Output at
PTR relief conditions (kW)
Approximate Roof space Required: Length x Width
- 1 Collector (mm)
- 2 Collectors (mm)
- 3 Collectors (mm)
Frost Protection
Rinnai Australia
MODEL NUMBERS AND SPECIFICATIONS
Enduro / Equinox
(SP200A) or
(SP200A FTC)
Flat plate
Copper
Aluminium
High Performance
1940 x
1025 x
80
33 / 35
1.3
8
1940 x 1025
1940 x 2130
1940 x 3235
* Standard version - no frost protection
FTC Version Frost Protection to -5°C
* FOR MORE INFORMATION ON FROST PROTECTION
- 11 - Solar Split Systems Operating / Installation Manual - Version 8 - 18/10/10
Excelsior
(EXT OR EXT FTC)
Flat plate
Copper
Copper
Sputtered Titanium Oxide
850 kPa
Aluminium
1964 x
1047 x
81
35 / 38
1.5
10
1.25
1940 x 1047
1940 x 2174
1940 x 3301
REFER TO WARRANTY BOOKLET
E-FROST
(HPFTC- 8-10)
Flat Plate /
Heat Pipe
Copper
Aluminium
High Performance
1940 x
1025 x
80
34
0.6
10
1940 x 1025
1940 x 2130
1940 x 3235
Frost Protection to -12°C.
Power must be on at the
pump and the controller
must be in low temperature
mode
(refer page 19).