Heat pump hot water system

Advertisement

Quick Links

Heat Pump Hot Water System
Operation & Installation Manual
MODELS
EHPS215VM
EHPS265VM

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai EHPS215VM

  • Page 1 MODELS EHPS215VM EHPS265VM Heat Pump Hot Water System Operation & Installation Manual...
  • Page 2 For continued safety of this appliance it must be installed and maintained in accordance with the manufacturer’s instructions. Standard: AS3498:2020 Standard: AS/NZS 2712:2007 Licence Number: SMK41306 Licence Number: WMK26792 SAI Global SAI Global Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 3: Table Of Contents

    Commissioning and Finishing the Installation �������������������������������������������������������������������������������������������� 20 Wiring Diagram ����������������������������������������������������������������������������������������������������������������������������������������������� 20 Operation of Controller ��������������������������������������������������������������������������������������������������������������������������������� 21 Controller Layout and Keys �������������������������������������������������������������������������������������������������������������������������� 21 Led Icons ��������������������������������������������������������������������������������������������������������������������������������������������������������� 22 Controller Functions and Operation ������������������������������������������������������������������������������������������������������������� 23 Wi-Fi Connection �������������������������������������������������������������������������������������������������������������������������������������������� 26 Contact Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 4: Warnings And Important Information

    For safety and warranty purposes, appliances that may be damaged or incorrect must not be installed or operated under any circumstances. Installation of damaged or incorrect appliances may contravene local government regulations. Rinnai disclaims any liability or responsibility whatsoever in relation to the installation or operation of damaged or incorrect appliances.
  • Page 5: Transport And Storage Of Appliance

    FROM VERTICAL The Rinnai Electric Heat Pump must be transported at an angle no greater that 45º from vertical. As the compressor unit is located at the top of the electric heat pump, should the heat pump be tilted at a greater angle than 45º from vertical, the lubrication oil within the compressor can run down into the mufflers.
  • Page 6: Scald Hazards

    NEVER…. Leave a toddler in the care of another child. They may not understand the need to have the water temperature set at a safe level. Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 7: Operating Principle

    During the occasional times when the ambient weather conditions aren’t suitable for the heat pump to operate, the electric element will provide heating to ensure a supply of hot water. SYSTEM SCHEMATIC FILTER FILTER EVAPORATOR HIGH PRESSURE SWITCH WATER TANK 4 WAY VALVE HEAT EXCHANGER COMPRESSOR MICRO-CHANNEL Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 8: Safety Devices

    If the valve leaks continuously, try easing the valve gear for a few seconds. This may dislodge any foreign matter and alleviate the problem. If this does not alleviate the problem contact Rinnai. Operate the easing gear regularly to remove any lime deposits and to verify that it is not blocked.
  • Page 9: Hydrogen Gas

    It is recommended that the anode be inspected at least every 5 years. The factory fitted Rinnai anode is Magnesium based. This anode is suitable when the total dissolved solids (TDS) content in the water supply does not exceed 600 mg/L, which is the case in most areas. In areas where the total dissolved solids (TDS) content in the water supply exceeds 600 mg/L the Rinnai aluminium based anode is required.
  • Page 10: Save A Service Call

    SAVE A SERVICE CALL Rinnai’s servicing network personnel are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance needs service, ring one of the service contact numbers on the back of this booklet.
  • Page 11 Ambient temperature sensor fault Sensor fault/Connection is loose Suction temperature sensor fault Sensor fault/Connection is loose *If an error code is displayed on the control unit please contact Rinnai Customer Care Immediately. Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 12: Specifications

    SPECIFICATIONS SPECIFICATIONS SYSTEM SPECIFICATIONS Model EHPS215VM EHPS265VM Net Weight / Gross Weight 108 kg / 121 kg 120 kg / 134 kg Tank Volume 215 L 265 L Sound Level 46 dB(A) Ambient Temperature Limits (for heat pump operation - element will -7°C to 43°C...
  • Page 13: Dimensions

    SPECIFICATIONS DIMENSIONS Model EHPS215VM EHPS265VM Cylinder height 1544 1764 Hot Outlet / PTR 1131 Cold water inlet Cylinder diameter Cylinder Diameter Height Hot Outlet / PTR Cold Inlet Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 14: Clearances

    Always allow 600mm minimum clearance on the fan discharge side and 200 mm minimum clearance on the fan suction side to allow for sufficient air flow through the fan. Allow 300mm minimum vertical clearance for service access. 150 mm 200 mm 600 mm 300 mm 200 mm 600 mm Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 15: Installation

    As this heat pump is highly efficient, the surrounding air temperature could be cooled by up to 4°C and condensate formed, the condensate outlet will need to be plumbed to a suitable drain. Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 16: Water Supply

    AS/NZS 3500.4 • An approved pressure limiting valve (supplied with some systems) is required if the maximum rated water supply pressure on page 12 is exceeded. • Tempering valve(s) or thermostatic mixing valve Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 17: Transport And Handling

    As a general good practice it is better to keep the compressor upright as much as possible. Returning the Rinnai Electric Heat Pump to a vertical position will allow the oil to properly flow back into the compressor motor. Tilting the heat pump beyond 45º from vertical will also place undue strain on compressor motor mounts and associated piping.
  • Page 18: Connect The Ptr Valve

    MUST EXCEED the total input from the heat pump. For example, the maximum output from the EHPS215VM is 4.5 kW (see the table on page 12). This is less than 46 kW, hence the supplied PTR valve is of sufficient capacity.
  • Page 19: Connect Condensate Drain Line

    Disconnect all power prior to installation and commissioning. This appliance is designed for single phase 240 Volts, AC mains electrical operation. IMPORTANT Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 20: Filling The System

    Also explain to the householder the importance of carrying out maintenance in accordance with this manual. Leave the manual with the householder. Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 21: Operation Of Controller

    Press the key and hold for 5s, enter into parameter setting interface Mode Press the key to change operation mode In parameter query interface, press the key enter into value setting or save the setting Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 22: Led Icons

    Displays Actual Current Water Temperature Set Water Temperature Displays Set Water Temperature Defrosting Defrosting Active Refrigerant Recovery Mode Active Maintenance Reminder Maintenance Required (See “Save a Service Call” on page 10) Error Warning Error Present Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 23: Controller Functions And Operation

    The mode name will show at the clock display for 8 seconds each time the “M” key is pressed. When unlocked, the display will show the clock. Press “M” key once to show the current Operation Mode. . Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 24 When the controller is in the normal display mode and the heat pump is ON, press “ “ and “ ” buttons together for more than 5 seconds to sterilise the water tank. The symbol “ “ will flash for 2 seconds then light up and the Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 25 Compressor working time before defrosting Measured value Link switch 0=Open; 1=Close Program code Show the code Dial switch 0=Open; 1=Close Dial switch 0=Open; 1=Close Phase detecting value 0=OK; 3=Lack phase; 4=Phase fault; 5=No connection Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 26: Wi-Fi Connection

    You will need to repeat step 5 if the icon stops flashing during the connection NOTE Connect to the SmartLife App as follows: i) Search for Device ii) Add Found Device iii) Connect to Wi-Fi Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 27 Control the Heat Pump with the App The main controls for the App are laid out as follows on the App. Adjust Temp Setting Turn Select Timer / On/Off Mode Check Operation Rinnai EHPS Heat Pump OIM - Issue 1...
  • Page 28: Contact

    (National calls from public phones in Australia are free.) For further information visit www.rinnai.com.au or email enquiry@rinnai.com.au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our National Help Line.