ESI Communications Servers Hardware Installation Manual

CO line connection

Note: For greatest simplicity, this section mentions each port card without the use of an "ESI," "E2-," or "CS-"
prefix, as cards otherwise are functionally identical — e.g., we refer to an E2-684 or CS-684 as just a "684."
Local loop
An ESI Communication Server's advanced CO line circuitry provides for open loop detection and the
system's built-in Caller ID interface. Loop start lines are connected via the last 6 pairs on each 66 block on the
612 and 684 cards.
Note: Observe correct order of connection to preserve proper rotary hunting of the CO lines.
T1/PRI
For T1 or PRI applications (only PRI on the ESI-50; it doesn't support T1), an ESI Communications Server
can use a compatible digital line card (DLC)
ESI-1000, ESI-600, ESI-200, ESI-100 — DLC and DLC12, each for either T1 or PRI.
ESI-50 — DLC82 for only PRI.
Depending on how you configure it, each supports either (a.) a single T1 circuit at 24 DS0 channels or (b.) a
PRI circuit supporting 23 "B" (bearer) channels and one "D" (data link) channel. The DLC12 and DLC82 each
also support 12 digital stations. The T1 or PRI line is connected via the last two pairs of the industry-standard
50-pin amphenol cable connector on the front of the DLC.
Each ESI Communications Server has a different maximum number of system-wide DLCs (see "Port card
options," page A.4). Partial T1 or PRI applications are supported through line programming.
Each DLC has built-in CSU functionality. The integrated CSU can be enabled or disabled via system
2
programming
. The following functionality is provided: line, payload, DTE and none (normal operation)
loopback modes with the ability to respond back controlled via system programming; alarm conditions, and
both ANSI T1.403 and TR 54016 performance messages for ESF only.
Important: On the ESI-50, the DLC82 may be installed in only slot 2.
If you're installing more than one T1 or PRI, the DLC in the lowest number slot will synchronize ("slave")
the system with the public network. The system will synchronize to only one clock source. Therefore, ESI
strongly recommends that the first DLC in the system be connected to the T1 or PRI that's connected
either to the local CO or the nationwide long-distance provider, either of which typically will provide very-
high-accuracy clocking (Strata 3). The DLC doesn't provide master or sub-master clocking for private-
network T1 spans.
(Continued)
1
You may wish to review "Port card options," page A.4.
2
See the explanation of Function 2124 in the ESI Communications Servers Programming Manual (ESI #0450-1050).
1
:
I.5
External connections