ENTER/EXIT PROGRAM MODE
HOLD DOWN KEY [8] UNTIL BEEP SOUNDS.
ENTER DEALER PROGRAM CODE.
SEGMENTS LIT
2:
PRESS "SET" (with no LED's lit)
TO SET 3-DIGIT LOCATION.
ST
3,2,1: ENTER 1
OF 3 DIGITS.
ND
3,2: ENTER 2
OF 3 DIGITS.
RD
3:
ENTER 3
DIGIT; DATA DISPLAYED.
2:
ENTER DEALER CODE (with all LED's
lit) TO EXIT.
L O CAT IO N KE Y S [ 1] (O R [ 8 ]) AND [ 2] (OR [ 3] )
BEEP = SHIFTED 1 LOCATION
NO BEEP = NO SHIFT

PROGRAMMING SHEETS

Programming Sheets similar to those that follow are com-
pleted when planning system features and communicator in-
formation for the particular installation. These sheets should
be retained for future reference. The Glossary contains infor-
mation and instructions for programming each feature.
General Programming Steps
1. Contact the central station to confirm receiver format, data
format, event codes, subscriber numbers and telephone
number(s). Two receiver descriptions and telephone num-
bers, and up to 4 Subscriber Identification Numbers may be
required.
2. Fill out the Programming Record Sheets by circling the
numbers representing the zone features or system features
to be programmed. Referring to the programming sheets
and the accompanying table, note that each program loca-
tion is assigned data values (1, 2, 4, 8) such that adding
any combination will produce a unique total (entry). Also
note that because the entry can be only one character, the
two-digit totals greater than 9 are replaced by zero and let-
ters B through F, as shown. Check the Glossary for guid-
ance in selecting "data" entries.
Example 2. Program Zones 1-7 to report on alarm. Referring to the Communicator Information section of the Programming
Sheet, Report on Alarm is contained in Locations 166 and 167. Circle data values for Zones 1-7.
Zone 1
Report on Alarm
166
Add the data values for Location 166: 1 + 2 + 4 + 8 = 15. From Table 3, 15 is programmed as an "F". Now add the data values
for Location 167: 1 +2 + 4 = 7. From Table 3, enter a "7" In Location 167.
MA1008e / 1008eM Installation Instructions
MAGNUM ALERT
3
2
1
LOCATION
1
PRIOR
5
CLEAR
9
F
COMPUTERIZED SECURITY SYSTEM
Zone 2
Zone 3
166
166
1
2
4
LOCATION
DATA
PAGE 1
2
3
4
NEXT
NEXT
DATA UP
6
7
8
PRIOR
DATA DOWN
ENTER/EXIT
*
P
A
#
B
SET
3. To program the subscriber PROM, follow the instructions
furnished with the programmer. While programming, re-
member to keep the address page number in mind, and be
sure that the position of the PAGE switch (PRO410/410M)
is set accordingly. Note: If using the Napco PRO410/410M
programmer, before attempting to program either page, be
sure that all data in programmer memory are erased (press
[ERASE], then [EXECUTE]).
4. Program the entries (data totals from Programming Record
Sheets in Step 2) into the respective locations. The display
will show the entry numerically, but will display "0" for the
number 10, and letters "B", "C", "D", "E", and "F" for the
numbers 11 through 15, respectively. To program a 10,
enter [0]. To program 11 through 15, enter [B] through [F]
respectively, if using the Napco PRO410/410M program-
mer to program a PROM, use the [PLUS] key to enter any
two or more digits that add up to the desired entry. To pro-
gram 13, for example, enter either [d] or [8] [PLUS] [5], or
[8] [PLUS] [4] [PLUS] [1], etc. Similarly, to add to an exist-
ing PROM location, first press the [PLUS] key, then the
complementary digit, otherwise the digit entered will re-
place the digit in memory. Refer to the PRO410/410M in-
structions for further programming information.
Zone 4
Zone 5
Zone 6
166
167
167
8
1
2
LED'S LIT
GREEN: .......... ENTER LOCATION DIGITS
YELLOW: ........ VIEW/CHANGE DATA
RED (RIGHT): . PAGE-1 LOCATION
ALL: ................ READY TO EXIT