Page 8
3. GETTING UP AND RUNNING
POWER-UP SEQUENCE
1. Referring to the Wiring Diagram, (a) connect the keypad to
the four keypad terminals 7 through 10 and (b) Install end-
of-line resistors (color code red/red/red) across each zone.
2. Connect an earth ground (cold-water pipe) to the left screw
that secures the circuit board to the cross rail.
3. Connect the power transformer to the AC Terminals 1 and
2 and plug the transformer into AC power.
4. Install the standby battery.
5. Check that the green STATUS LED on the keypad is lit.
6. Install loop wiring to zone terminals and relocate resistors
to end of loops. Recheck green STATUS LED.
7. If reporting to a central station, connect a telephone con-
necting cord to the TELCO terminals: green to 23; red to
24; and PHONE terminals: brown to 25; gray to 26. Then
see CENTRAL-STATION REPORTING.
DEFAULT PROGRAM
The MA1008e will function as a local alarm control panel
right out of the box! The following default program is entered
at the factory. It is the installer's responsibility to add, change
and/or delete features in accordance with these instructions
to customize the system to the user's requirements and to
conform to local codes.
•
Arm/Disarm Code: 1,2,3 (User 1)
•
User Program Code: 1,2,3,4,5,6
•
Dealer Program Code: 4,5,6,7,8,9
•
Exit/Entry (Entry Delay 1): Zone 1
•
Entry Delay 1: 30 seconds
•
Entry Delay 2: 30 seconds
•
Exit Delay: 45 seconds
•
Priority: Zones 1-7
•
Selective Bypass: Zones 1-7
•
24-Hour Protection: Keypad Panic
•
Auto Reset: Zones 1-7; Keypad Panic
•
Swinger Shutdown: Zones 1-7; Keypad Panic
•
Chime: Zone 1
•
Chime Time: 2 seconds
•
Burglary Output: Zones 1-7; Keypad Panic
•
Burglary Timeout: 15 minutes
•
Fire Timeout: 15 minutes
•
Download with Answering Machine enabled
•
Auto-Reset After Alarm Timeout enabled
•
Power-Up In Last State enabled
•
Pulsing Fire Output enabled
•
Reset Fire enabled
•
Keypad Tactile Beep enabled
•
Keypad Panic enabled
•
Communicator-Confidence Test enabled
•
Alarm/Trouble Codes,
- Zones 1-7: 31-37
- Panic: 21
- Fire: 11
- Ambush: 22
- Fire Trouble: F1
- No AC: F9
- Low Battery: F8
•
Restore Codes,
MA1008e / 1008eM Installation Instructions
- Zones 1-7: E1-E7
- Fire: E1
- Fire Trouble: EF
- No AC: E9
- Low Battery: E8
•
Closing Codes, Users 1-4: C1-C4
•
Opening Codes, Users 1-4: B1--B4
•
Force-Arm Code: F
CENTRAL STATION REPORTING
The following additional programming is required for central
station reporting.
•
Report on Alarm
•
Subscriber ID (Account) Numbers, Groups 1 & 2*
•
Receiver Format*
•
Data Format*
•
Telephone Number*
*Obtained from central station.
Note: Remember, for optimum security, the following code
must also be reprogrammed:
•
User-1 Code (see Programming User Codes, below).
For other programming, see Dealer Keypad Program-
ming (Section 4) and the programming aid shown in Fig.
3.
USER KEYPAD PROGRAMMING
Programming User Codes
Note: The User Program Mode is disabled for the first
three minutes after power-up to allow you to use the Dealer
Program Code. To cancel the delay, hold down Key [9].
Up to eight different Arm/Disarm Codes may be entered
into the control panel using the keypad. User Code 5 may be
programmed as a Service Code, a special user code in-
tended for temporary or occasional use only (see Service
Code).
To program a User Code:
1. Hold down Key [8] until the sounder beeps, then enter
the User Program Code. (The default User Program
Code is 1,2,3,4,5,6, but this code must be repro-
grammed). When the User Program Code has been
entered, the first three LED's on the keypad will flash
and the sounder will beep rapidly, indicating the User
Program Mode.
2. Now enter up to eight codes using any combination of
up to four digits (digits 1-9 only).
Examples:
Press:
[B], [1], then any 4 digits = User 1's code*
[B], [5], then any 4 digits = User 5's code**
[B], [8], then any 4 digits = User 3's code
*Default User-1 Code 1,2,3 must be changed.
**May be programmed as Service Code or Arm-Only
Code.
3. To exit User Program Mode, press [B] twice.
The numbers selected are the only codes recognized by
the system. Each user should be assigned his own dissimilar
code and cautioned against divulging that code to anyone else
Thus, should it became necessary to remove a user from the
L
NAPCO Security Systems