Downloading From A Computer; Prom Programming - NAPCO MAGNUM ALERT 1008e Installation Instructions Manual

Control panel / communicator
Table of Contents

Advertisement

LOCATION XXX
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
Table 3. Determining data entry for a location. Numbers in pa-
rentheses indicate selected zones or features.
(See Programming Sheet.)
DOWNLOADING FROM A COMPUTER USING NAPCO
SOFTWARE AND INTERFACE
Local Downloading
Data may be locally downloaded with the use of PCL2000
Local Download Cable, which is supplied with the PCI2000
interface. The panel need not be wired nor the keypad con-
nected.
Also refer to the instructions included with the
PCI2000.
1. Referring to the PCI2000 Wiring Diagram, connect the
PCL2000 Local Download Cable between the modem
LINE connector and the control panel TELCO terminals.
(Remove the plug shown coming from the PCI2000-J5).
2. With the control panel unpowered, set up the computer for
a Function-6 Method download.
3. When a high-pitched tone is heard at the modem, power
up the panel (connect the battery or transformer). A con-
nection will automatically be established, ignoring the
status of the zones.
4. Make all required selections and download the program.
5. After the computer indicates a successful download, termi-
nate the connection, then remove power to the panel.
Remote Downloading
Data may be remotely downloaded to the panel via tele-
phone lines using an IBM PC-compatible computer with Napco
PCD2000 software and PCI2000 interface. Onscreen prompt-
ing and the extensive use of help menus simplify program-
ming, and an error-checking mode locates omissions and in-
compatible data to reduce the possibility of mistakes. Remote
downloading requires (a) a modem compatible with the
PCI2000 and (b) PCD2000 software Version 2.E or higher.
Note: Remote downloading may be disabled through pro-
gramming and must be disabled in UL installations.
A program may be downloaded remotely using either of the
following procedures.
Callback Method. This method is used to download to an
unattended panel. The MA1008e will accommodate an an-
L
NAPCO Security Systems
ENTRY
blank
1
2
3
(4)
4
(4)
5
(4)
6
(4)
7
(8)
8
(8)
9
(8)
0 (10)
(8)
B (11)
(4)
(8)
C (12)
(4)
(8)
D (13)
(4)
(8)
E (14)
(4)
(8)
F (15)
swering machine at the site if line seizure is used on the house
phones. Program a "1" in Location 082 (Enable Download
with Answering Machine). Refer to the instructions furnished
with the PCD2000 for details. Note: The number of rings pro-
grammed into the panel must exceed that of the answering
machine.
Function-6 Method. Call the central station from the site
to request a Manual Download. During this procedure, voice
contact will be lost, therefore both the installer and the com-
puter operator should be familiar with the operation. When a
high-pitched tone is heard at the site phone, arm the panel,
disarm, then access Hold-Down Function 6 (Manual
Download) within 5 seconds; the site phone will go dead.
Hang up the phone and wait for a call from the central station
confirming a successful download.
Auto-Download Method. Napco PCD2000 Software Ver-
sion 2.E and later includes PC-Preset, a utility wherein blocks
of up to 99 programs each may be preset for remote uploading
or downloading from the installation site while the computer is
unattended. The Auto-Download ID Number identifies the pro-
gram in the computer that will be selected. (Note that the
Dealer Program Code in the PCD2000 must agree with that of
the control panel for the remote connection to be established.)
At the installation site, the Auto-Download ID Number cor-
responding to that in the computer is programmed into the
panel, along with the Callback Telephone Number of the com-
puter. To execute an Auto-Download, arm the panel, disarm,
then access Function 6 within 5 seconds.

PROM PROGRAMMING

A blank DD493BNK PROM may be programmed using a
PRO410 or PRO410M Programmer. See General Program-
ming Steps and the manual furnished with the programmer for
operating instructions, and also the Programming Record
Sheets that follow. PROM programming may be used to pro-
gram all features except the Dealer Program Code (Locations
244-249) and User Arm/Disarm Codes.
The following programming is required:
Page-0, Location 083: "5"
Page-1, Location 251: "C"
Page-1, Location 252: "4"
Transferring Memory from PROM
Data programmed in the PROM are saved in memory as
follows:
1. At the panel, with AC and battery power off, insert the
programmed PROM into the MEMORY CHIP socket.
Align the dot on the PROM with the dot on the circuit
board.
2. Apply ac power. Enter the Dealer Program Mode: Hold
down Key [8] until the function beep sounds, then enter
the Dealer Program Code.
3. Exit the Dealer Program Mode: Hold down Key [8] until
the beep sounds, then enter the Dealer Program Code.
4. An "L" or "LOADING PROM" will display at the keypad.
When loading is complete, remove both AC and battery
power, remove the PROM from the socket, then power
up normally.
MA1008e / 1008eM Installation Instructions
Page 13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnum alert 1008em

Table of Contents