ZONE FEATURES
SWINGER SHUTDOWN
NO END-OF-LINE RESISTOR
CHIME ZONE
NEVER ARM
PIR ZONE
UNTIMED OUTPUT
(ONTO LUG 15)
ENABLE KEYPAD SOUNDER
ON ALARM
DAY ZONE
PRIORITY ZONE WITH BYPASS
(SEE NOTE 1)
PRIORITY ZONE
REMOVE AUTO BYPASS
(SEE NOTE 1)
SELECTIVE BYPASS
GROUP BYPASS
24-HOUR PROTECTION
AUTO-RESET
EXIT / ENTRY ZONE
(ENTRY DELAY 1)
EXIT / ENTRY ZONE
(ENTRY DELAY 2)
EXIT / ENTRY FOLLOWER
ABORT DELAY
BURGLARY OUTPUT
7mS LOOP RESPONSE
(SEE NOTE 2)
50mS LOOP RESPONSE
(SEE NOTE 2)
FIRE ON BURGLARY ZONE
(SEE NOTE 3)
KEYPAD CODES (DO NOT ENTER ZEROS)
AMBUSH
USER PROGRAM CODE
236
237
238
239
(1)
(2)
USER 1
316
317
318
319
320
USER 5
332
333
334
335
336
ENTRY TOTAL:
PROGRAMMER DISPLAYS
See Note 5
NOTES: (1) If programming PRIORITY ZONE WITH BYPASS, do not program REMOVE AUTO BYPASS. (2) If neither 7mS nor 50mS LOOP RESPONSE is pro-
grammed, Loop response will be 750mS. (3) FIRE ON BURGLARY ZONE's must also be programmed for 24-HOUR PROTECTION, but for no other zone features
except UNTIMED OUTPUT. (4) The Dealer Program Code must not start with the same numbers as the User Program Code. (5) ● (dot) or blank for no entry. (6) To
conform with Telephone Company convention, program zeros in Telephone Numbers, Alarm Codes and Subscriber ID Numbers as an entry total of 10. (Press DATA
UP button until "0" is displayed; in PRO410, press Key [0].) (7) Zone "8" for wireless operation only. To use as other than keypad Panic, also program DIRECT KEY-
PAD PANIC TO AMBUSH (see GLOSSARY).
L
NAPCO Security Systems
PROGRAMMING RECORD SHEET FOR THE MA1008e
Zone Features & Keypad Codes - Default programming shown in parentheses.
GROUP 1
ZONE
1
2
3
4
5
6
184
1
2
4
8
1
2
086
1
2
4
8
1
2
088
1
2
4
8
1
2
090
1
2
4
8
1
2
092
1
2
4
8
1
2
096
1
2
4
8
1
2
164
1
2
4
8
1
2
186
1
2
4
8
1
2
188
1
2
4
8
1
2
190
1
2
4
8
1
2
192
1
2
4
8
1
2
194
1
2
4
8
1
2
196
1
2
4
8
1
2
198
1
2
4
8
1
2
200
1
2
4
8
1
2
202
1
2
4
8
1
2
204
1
2
4
8
1
2
206
1
2
4
8
1
2
208
1
2
4
8
1
2
210
1
2
4
8
1
2
214
1
2
4
8
1
2
216
1
2
4
8
1
2
306
1
2
4
8
1
2
SEE NOTE 4
240
241
242
243
(3)
(4)
(5)
(6)
USER 2
USER 3
321
322
323
324
325
USER 6
USER 7
337
338
339
340
341
1
2
3
4
5
6
1
2
3
4
5
6
K/P
FIR
FIR
AMB
TBL
7
8
085
4
8
087
4
8
089
<--(ALSO SEE TIMES & TIMEOUTS, LOC. 230-231)
4
8
091
4
8
<--(SEE NOTE 7)
093
<--(ALSO SEE TIMES & TIMEOUTS, LOC. 094-095)
4
8
<--(SEE NOTE 7)
097
098
4
8
1
2
4
165
4
8
187
TRANSMITTER ZONE MAP
4
8
(FOR WIRELESS SYSTEMS ONLY)
189
TX#
LOC
4
8
191
1
308
4
8
2
309
193
3
310
4
8
4
311
195
REFER TO R1000 RECEIVER INSTRUCTIONS
WI604 FOR TRANSMITTER MAPPING AND
4
8
LEARNING INSTRUCTIONS AND OTHER WIRE-
197
LESS INSTALLATION INFORMATION.
4
8
199
4
8
201
4
8
203
<--(ALSO SEE TIMES & TIMEOUTS, LOC. 218-219; 220-221)
4
8
<--(SEE NOTE 7)
205
<--(ALSO SEE TIMES & TIMEOUTS, LOC. 218-219; 222-223)
4
8
<--(SEE NOTE 7)
207
<--(SEE NOTE 7)
4
8
<--(ALSO SEE TIMES & TIMEOUTS, LOC. 232-233)
209
4
8
211
<--(ALSO SEE TIMES & TIMEOUTS, LOC. 224-225; 228-229)
4
8
215
4
8
NOTE:
For wireless systems, refer to R1000 Receiver
Installation Instructions (WI604) for Transmitter Mapping
217
Locations 308-315.
4
8
307
<--(SEE NOTE 7)
4
8
DEALER PROGRAM CODE
244
245
246
247
248
249
(4)
(5)
(6)
(7)
(8)
USER 4
326
327
328
329
USER 8
342
343
344
345
7
8
9
10
11
12
7
8
9
0
B
C
See Note 6
MA1008e / 1008eM Installation Instructions
GROUP 2
DAY
TST
NO
LOW
TBL
TMR
AC
BAT
ARM
099
8
1
2
4
8
ZONE
TX#
LOC
ZONE
1
312
2
313
3
314
4
315
(9)
330
331
346
347
13
14
15
D
E
F
Page 15