Programming User Codes - NAPCO XP-400 Using Instruction

Express series
Hide thumbs Also See for XP-400:
Table of Contents

Advertisement

Your Installer has assigned a User 1 Code which may be used to not only Arm and Disarm the system,
but also to enter the User Program Mode, where you can program and/or reprogram up to 4 User Codes.
The following explains how you will use this code to program or erase additional user codes.
Entering the User Program Mode
Press
followed by
A
8
Lights will flash, and the keypad will beep 4 times. You are now in the User Program mode. Zone lights
1 through 4 will light to indicate any User Codes presently programmed.
Programming / Reprogramming User Codes
1
Press the User number to be programmed. (For example, press
The keypad will beep 2 times and the corresponding zone light will flash to indicate the user number
you are about to program.
2
Press in the 4 digits of the new User 2 code, the keypad will beep 4 times.
3
If there are more user codes to be programmed, return to step 1 above; otherwise, go to Exiting the
User Program Mode below.
Erasing a User Code
1
Press the User number to be erased. The keypad will beep 2 times and the corresponding zone light
will flash to indicate the user number you are about to erase.
2
Press
. The zone light will go out to indicate that the user code has been erased.
D
3
If there are more user codes to be erased, return to step 1 above; otherwise, go to Exiting the user
Program Mode below.
Exiting the User Program Mode
When you are finished programming or erasing User codes, press
and then enter the User 1 code. The

Programming User Codes

Armed,
Status and
W
X
to program the User 2 code).
2
to Exit the User Program Mode.
B
System
H
11