Sony HKCU1001 Installation Manual page 19

Hd camera control unit
Hide thumbs Also See for HKCU1001:
Table of Contents

Advertisement

Ref.No. Name
S412
SYNC
S413
Factory use
S416
Co-AX
S418
48V/50V/60V
S419
720/Psf/I
S420
1001/REMOTE/1000
RV701
27M FREQ
RV702
CK-DUTY
HDCU3300/IM (J,E)
Function
Sets the SYNC signal output from the SYNC terminal to HD or SD.
HD : HD-SYNC signal output
SD : SD-SYNC signal output
Not used (D-S-Fi)
Multi-Format setting (Camera transmission format)
When the operation clock frequency setting switch (S420) is set to Local, the main
video format of CCU is set as in the following table. The output transmission format
of CHU is also set in the same way. (Refer to the table below.)
Multi-Format setting (Camera transmission format)
When the operation clock frequency setting switch (S420) is set to Local, the main
video format of CCU is set as in the following table. The output transmission format
of CHU is set in the same way. (Refer to the table below.)
FORMAT
S420
1080-60 (or 59.94) i
1.000 (or 1.001)
1080-30 (or 29.97) PsF
1.000 (or 1.001)
1080-50 i
1.000
1080-25 PsF
1.000
1080-24 (or 23.98) PsF
1.000 (or 1.001)
720-60 (or 59.94) P
1.000 (or 1.001)
720-50 P
1.000
Operation clock frequency setting
1.001 : Sets the field frequency of CCU to 59.94, 29.97, 23.98 Hz.
1.000 : Sets the field frequency of CCU to 60, 50, 25, 24 Hz.
REMOTE : Can be set from MSU.
* Can also perform remote/local setting of video output format from CCU.
Volume that adjusts the free-run frequency of 27M-VCO (X701). Must be
readjusted when replacing X701.
Volume that adjusts the clock duty of the 74 MHz clock.
S418
S419
60 V
Intr
60 V
PsF
50 V
Intr
50 V
PsF
48 V
PsF
60 V
720 P
50 V
720 P
Factory default setting
SD
OFF
Fiber
60
INTR
REMOTE
1-13 (E)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hkcu1003Hkcu1005Hdcu3300

Table of Contents