Rf Jam Detect Zone; Receiver Software Default - DSC LCD5501Z32-433 NA Installation Manual

Table of Contents

Advertisement

O
T
H
To program the wireless supervisory window:
1. Enter [ ][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter into Receiver Programming.
3. Enter sections [81].
4. Enter the time period for the supervisory window (valid entries are 01-24 hours).
5. To exit press [#].
Disable/Enable Zone Supervision
All wireless zones have supervision enabled by default. To disable supervision for
any zone, enter the following at any system keypad:
1. Enter [ ][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter the PC5132 Module Programming.
3. Enter sections [82], [83], [84] and [85]. Disable or enable supervision for each
wireless zone by turning each relevant option on or off.
4. To exit press [#].

4.4 RF Jam Detect Zone

For RF jamming detection to work, you must select an unused zone to be used as
the RF Jam Detect zone. When the receiver detects an attempt to jam the RF
signal, the RF Jam Detect zone will be violated and the system will generate a
tamper signal. When the jamming signal is gone, the RF Jam Detect zone closes
and the system sends a tamper restore signal.
To enable RF jamming detection:
1. Enter [ ][8] [Installer's Code].
2. Enter programming section [804].
3. Select an unused zone to be the RF Jam Detect zone. Enter the 2-digit number
([01] to [32]) of the RF Jam Detect zone on the keypad, then program the
serial number as [200000].
3. Enter section [93]. Enter the 2-digit number of the RF Jam Detect zone ([01] to
[32]) in the programming section.
4. Disable supervision for the RF Jam detect zone by turning the relevant option
off in section [82], [83], [84] or [85]. (See section 4.3 for more information.)
5. RF jamming detection is now enabled. To exit Installer programming, press [#].

4.5 Receiver Software Default

Returning the receiver programming to factory default settings is a quick way to
remove all the enrolled devices from the system and reset all the programming in
section [804].
NOTE: Performing this procedure will not change any programming sections except
[804]. Resetting the control panel to factory default settings will not return the
PC5132 to factory default settings.
E
R
P
R
O
G
R
A
13
M
M
I
N
G

Advertisement

Table of Contents
loading

Table of Contents