Installation Of Cold Control; Wiring Of Control System; Connection Of 115 Volt Ac Supply - Dometic 57908.321 Installation Instructions Manual

Table of Contents

Advertisement

A. 579, 590, 591 AND 595 SERIES
1. Insert the Freeze Control Sensor approximately 1" into the fins of the evaporator coil as shown in FIG. 9. Bend fins
over sensor to secure in place.
2. Plug the freeze control sensor cord into the mating connector on the Electronic Control Kit. These connectors are
polarized and will easily snap together. DO NOT FORCE.
579, 590 & 595 FREEZE CONTROL
Bend fins over
sensor to hold
in place
Freeze control
sensor
Insert Freeze
Control Sensor
at a slight angle
between bottom
coil approximately 1"
Freeze Control with
wires to the right side
FIG. 9
B. 600 & 630 SERIES
1.
Insert the Freeze Control Sensor approximately 1" into the evaporator coil fins located at the right side of the evaporator,
as shown in FIG. 10. Bend fins over sensor to secure in place.
2. Plug the freeze control sensor cord into the mating connector on the Electronic Control Kit. These connectors are
polarized and will easily snap together. DO NOT FORCE.
A. CONNECTION OF 115 VOLT AC SUPPLY
1. Reach up into the return air opening of the air conditioner and pull the unit electrical cord down for later installation. See
FIG. 11.
FIG. 11
DC Power
Supply
INSTALLATION INSTRUCTIONS DUCTED CCC

8. INSTALLATION OF COLD CONTROL

Remove
Hang
Tag

8. WIRING OF CONTROL SYSTEM

AC Power
Supply
Roof
Gasket
Pull Electrical
Cord Down
600 & 630 FREEZE CONTROL
Remove
Hang
Tag
Freeze Control with wires.
FIG. 10
Disconnect 115 volt AC. Failure to follow
these instructions could create a shock haz-
ard causing death or severe personal injury.
This product is equipped with a 3-wire
(grounded) system for protection against
shock hazard. Make sure that the appliance
is wired into a properly grounded 115 volt AC
circuit and the polarity is correct. Failure to
do so could result in death, personal injury
or damage to the equipment.
11
Bend fins over
sensor to hold
in place
Freeze control
sensor
Insert Freeze Control
Sensor at a slight angle
between bottom coil
approximately 1"
WARNING
!
WARNING
!

Hide quick links: