Page 1
CLIMATE CONTROL AIR CONDITIONERS Brisk Air (457915, 459516), Brisk II (B57915, B59516), High Performance (540315, 540316), Blizzard NXT (H540315, H540316), Penguin (640312, 640315, 640316), Penguin II (640312C, 640315C, 640316C), FreshJet (FJX3473, FJX3573) Value Air Distribution Box, Mechanical Installation and Operation Manual ..2...
• Use for purposes other than those described in the • Use only Dometic replacement parts and operating manual components that are specifically approved for use with the product.
Components and component locations may vary according to specific product models. Measurements may vary ±0.38 in. (10 mm). 3 .1 Tools and Materials Dometic recommends that the following tools and materials be used. Recommended Tools and Materials Framing Wood...
Value Air Distribution Box (ADB), Mechanical General Information 3 .4 Rooftop Component Dimensions 3 .4 .2 Brisk Air by Model This section provides the external dimensions and clearance measurements of the rooftop component. 3 .4 .1 FreshJet 3 Brisk Air (457915, 459516) 13.1 in.
Page 6
General Information Value Air Distribution Box (ADB), Mechanical 3 .4 .3 Brisk II 3 .4 .4 Blizzard NXT 5 Blizzard NXT (H540315, H540316) 4 Brisk II (B57915,B59516) 13.9 in. (353 mm) 4.0 in. (102 mm) 13.7 in. (349 mm) Front of Unit Clearance 40.0 in.
Page 7
Value Air Distribution Box (ADB), Mechanical General Information 3 .4 .5 High Performance 3 .4 .6 Penguin 6 High Performance (540315, 540316) 7 Penguin (640312, 640315) 13.0 in. (330 mm) Front of Unit 9.5 in. (241 mm) 4.0 in. (102 mm) 39.6 in.
General Information Value Air Distribution Box (ADB), Mechanical 3 .4 .7 Penguin II 3 .5 ADB Component Dimensions This section provides the internal dimensions of the ADB component. 8 Penguin II (640312C, 640315C, 640316C) 9 Dimension Measurements 10.4 in. (264 mm) 4.0 in.
Value Air Distribution Box (ADB), Mechanical General Information 3 .6 Placement Requirements 3 .6 .1 Tilt Requirements When measuring for placement, confirm the following The rooftop component is specifically designed for tilt requirements. installation on the roof of an RV. To determine where to place the rooftop component, consider the following 1.
Circuit protection: a time delay fuse or circuit breaker is required. Dometic Corporation gives general guidelines for generator requirements. These guidelines come from experiences people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered. Generators may lose power at high altitudes and from lack of maintenance.
Value Air Distribution Box (ADB), Mechanical Wiring Diagrams 5 Wiring Diagrams Compressor This section provides the wiring diagrams for the Motor product. GRN/YEL O.L. Compressor 6 Pin Conn Motor GRN/YEL O.L. 6 Pin Conn Comp. Startter Herm GRN/YEL *Start PTCR Run Cap *Not used on some models...
Pre-Installation Value Air Distribution Box (ADB), Mechanical NOTICE: Failure to follow these notices could result in damage to the rooftop component and/ or the RV . GRN/YEL • Never create a low spot on the RV roof. • Maintain the structural integrity of the RV roof. The roof must be designed to support 130 lbs (59 kg) when the RV is in motion.
Page 13
Value Air Distribution Box (ADB), Mechanical Pre-Installation 6 .2 .1 Using an Existing Roof Vent 6 .2 .2 Making a New Roof Opening Opening If the roof has an existing roof vent, see “Using an Existing Roof Vent Opening” on page 13. If the roof does not have an existing roof vent, skip to “Making a New Roof Opening”...
Pre-Installation Value Air Distribution Box (ADB), Mechanical 2. Route the 115 VAC power supply wire from the time-delay fuse or circuit breaker box to the roof opening. Use a listed/certified non-metallic sheathed single strand cable. See “Specifications” on page 10. If an AC or a vent fan were removed, the existing power supply wire may be used provided it is of the proper type, size, and location, and if it is correctly fused.
Value Air Distribution Box (ADB), Mechanical Installation 4. Lift and place the rooftop component over 3. Reach up into the return air opening of the the prepared opening using the gasket on the rooftop component and pull the rooftop component rooftop component as a guide.
Page 16
Installation Value Air Distribution Box (ADB), Mechanical 21 Stacking the Foam Dividers and Placement Location Stacked Foam Foam Divider - Dividers 0.4 in. (10 mm) (2) Roof Thickness Foam Divider - 1.2 in. (30 mm) (3) Top Foam - ADB Adaptor (1) 0.4 in. (10 mm) (1) Top Foam Ring - 0.4 in.
Page 17
Value Air Distribution Box (ADB), Mechanical Installation 7 .1 .1 Roof Thickness 1 .25 to 5 .5 in . (32 to 152 mm) All Models 1.25 in. 1.5 in. 2.0 in. 2.5 in. 3.0 in. 3.5 in. 4.0 in. 4.5 in. 5.0 in. 5.5 in. Roof (64 mm) (76 mm) (102 mm) (114 mm) (127 mm)
Page 18
Installation Value Air Distribution Box (ADB), Mechanical 7 .1 .2 Roof Thickness 6 .0 - 7 .5 in . 1. Using the tables, determine the number and combination of foam dividers required based on the (152 to 191 mm) roof thickness. All Models 6.0 in. 6.5 in. 7.0 in.
Value Air Distribution Box (ADB), Mechanical Installation 2. Use the following figures to determine the proper mounting pattern and bolt location. 24 Mounting Bolt Pattern - All Models 23 Passing the Wire Through the Filter Notch Filter ADB Second Slot Filter Notch 115 VAC Power Supply Wire and 6-pin Unit Electrical Cord...
Installation Value Air Distribution Box (ADB), Mechanical 7 .3 Wiring the Unit to the Power 5. Route the 115 VAC power supply wire from the roof opening to the junction box location. Supply 6. Thread the 115 VAC power supply wire through the strain relief.
Value Air Distribution Box (ADB), Mechanical Operation 4. Tape the connectors to the 115 VAC power supply wire to ensure they do not vibrate loose. 5. Push the connected wires into the junction box. 6. Align the junction box cover to the notch on the side of the junction box.
Operation Value Air Distribution Box (ADB), Mechanical 8 .1 Understanding the Controls 2. Select the coolness level that best satisfies your needs: This section describes the operating controls. – Low Cool (shorter dash) maintains the room at the current comfort level. Normally, Low Cool is used for nighttime operation.
Value Air Distribution Box (ADB), Mechanical Maintenance 9 Maintenance This section describes how to maintain a clean air filter. 1. Periodically (or a minimum of every two weeks of This section describes routine activities to maintain operation) remove the return air filter located behind properly working system components.
For a more permanent solution to high heat gain, accessories like the Dometic outdoor patio or window awnings reduce the effects of direct sunlight. During normal operation, this product is designed to remove a certain amount of moisture from the air, depending on the size of the space being conditioned.
Page 25
Value Air Distribution Box (ADB), Mechanical Disposal...
Page 26
Disposal Value Air Distribution Box (ADB), Mechanical...
Page 27
Value Air Distribution Box (ADB), Mechanical Disposal...
Page 28
Mobile living made easy. dometic .com YOUR LOCAL YOUR LOCAL YOUR LOCAL DEALER SUPPORT SALES OFFICE dometic .com/dealer dometic .com/contact dometic .com/sales-offices...