Advertisement

USA
SERVICE OFFICE
Dometic Corporation
2320 Industrial Parkway
Elkhart, IN 46516
574-294-2511
CANADA
Dometic Corporation
46, Zatonski, Unit 3
Brantford, ON N3T 5L8
CANADA
519-720-9578
For Service Center
Assistance Call:
800-544-4881
INSTALLATION
INSTRUCTIONS
REVISION
Form No. 3109270.102 8/07
(Replaces 3109270.094)
(French 3109537.096)
©2007 Dometic Corporation
LaGrange, IN 46761
520 Series DUO-THERM HP
530 Series DUO-THERM HP HEAT PUMP
591 Series HEAT PUMP
595 Series QUICk COOL
Roof Top Air Conditioners & Heat Pumps
Used With Part No. 3109226.005 & 3109407.001
Comfort Control Center Electronic Control kit
3109228.001 (White) Comfort Control Center
3109228.019 (Black) Comfort Control Center
THIS UNIT IS DESIgNED FOR OEM INSTALLATION
ALL INITIAL INSTALLATIONS MUST BE APPROVED BY
This manual must be read and un-
derstood before installation, ad-
justment, service, or maintenance
is performed. This unit must be
installed by a qualified service
technician. Modification of this
product can be extremely hazard-
ous and could result in personal
injury or property damage.
Important:
These instructions must
stay with unit. Owner read carefully.
579 Series BRISk AIR
590 Series BRISk AIR
600 Series PENgUIN
630 Series PENgUIN
Ducted Installation Using
DOMETIC CORPORTION
Lire et comprendre ce manuel avant
de procéder à l'installation, à des ré-
glages, de l'entretien ou des réparations.
L'installation de cet appareil doit être
effectuée par un réparateur qualifié.
Toute modification de cet appareil
peut être extrêmement dangereuse et
entraîner des blessures ou dommages
matériels.
MODELS
57908.321
57915.531
57908.521
57915.536
57912.321
57915.541
57912.531
57915.546
57912.532
57915.621
57912.621
57915.622
57912.622
57915.626
57912.631
57915.631
57915.321
57915.731
57915.322
57915.741
57915.331
59016.521
57915.336
59016.526
57915.421
59016.531
57915.422
59016.621
57915.521
59136.321
57915.522
59136.331
RECORD THIS UNIT INFORMATION
FOR FUTURE REFERENCE:
Model Number
Serial Number
Date Purchased
OR
TM
TM
59136.336
59516.631
600315.421
59136.521
59516.731
630035.321
59136.531
59528.601
630035.421
59136.536
59529.531
520300.501
59136.621
59529.601
520310.501
59136.631
59529.631
520315.501
59516.303
59530.531
520315.506
59516.331
59530.532
520316.501
59516.336
59530.536
520316.506
59516.501
59530.601
530515.501
59516.506
59530.631
530515.606
59516.531
59530.632
530516.501
59516.536
600312.321
530516.506
59516.601
600312.421
59516.603
600315.321
59516.606
600315.326

Advertisement

Table of Contents
loading

Summary of Contents for Dometic 57908.321

  • Page 1 59016.531 59516.536 600312.321 530516.506 Form No. 3109270.102 8/07 57915.422 59016.621 59516.601 600312.421 (Replaces 3109270.094) 57915.521 59136.321 59516.603 600315.321 (French 3109537.096) 57915.522 59136.331 59516.606 600315.326 ©2007 Dometic Corporation Important: These instructions must LaGrange, IN 46761 stay with unit. Owner read carefully.
  • Page 2: Safety Instructions

    CCC Ducted Installation Instructions 1. gENERAL INFORMATION SAFETY INSTRUCTIONS A. Product features or specifications as described or il- lustrated are subject to change without notice. This manual has safety information and instruc- B. This air conditioner is designed for: tions to help users eliminate or reduce the risk 1.
  • Page 3: Specifications

    CCC Ducted Installation Instructions...
  • Page 4 CCC Ducted Installation Instructions...
  • Page 5 CCC Ducted Installation Instructions...
  • Page 6 1. Up to an 8° slant to either side or front-to-back is B. Dometic Corporation will not be liable for any dam- acceptable on 600 and 630 series air condition- ages or injury incurred due to failure in following these ers/heat pump.
  • Page 7: Air Distribution System

    It is the responsibility of the installer to in- sure the duct work will not collapse or bend during and after the installation. Dometic Corporation will not be liable for roof struc- tural or ceiling damage due to improperly insulated, sealed or collapsed duct work.
  • Page 8 5. AIR DISTRIBUTION SYSTEM INSTALLATION A. Dometic Corporation recommends the basic configuration shown on page 8 for installing this air conditioner/heat pump sys- tem. We have found through testing that this configuration works best in most applications of this air conditioner/heat pump system.
  • Page 9 CCC Ducted Installation Instructions C. AIR DISTRIBUTION DUCT INSTALLATION Install the Air Distribution Ducts in the RV Roof Cavity. The Distribution System must meet: a. RV’s requirements b. System requirements listed in Section 4 on page 6 of this Manual. Terminate the start of the Duct at the back edge of the 14-1/4"...
  • Page 10 CCC Ducted Installation Instructions 6. COMFORT CONTROL CENTER , REMOTE SENSOR & CABLE INSTALLATION A. LOCATION FOR COMFORT CONTROL CENTER AND REMOTE TEMPERATURE SENSOR 1. The proper location of the Comfort Control Center (CCC) is very important to ensure that it will provide a comfortable RV temperature.
  • Page 11: Placing The Air Conditioner On The Roof

    CCC Ducted Installation Instructions FIg. 6 7. PLACINg THE AIR CONDITIONER ON THE ROOF A. Remove the air conditioner from the carton and discard carton. The unit mounting bolts and literature are in a separate plastic bag. Be sure to place this information in the RV. B.
  • Page 12 CCC Ducted Installation Instructions 8. INSTALLATION OF COLD CONTROL A. 520, 530, 579, 590, 591 AND 595 SERIES 1. Insert the Freeze Control Sensor approximately 1" into the fins of the evaporator coil as shown in FIG. 9. Bend fins over sensor to secure in place. 2.
  • Page 13 CCC Ducted Installation Instructions 2. Route the previously run AC power supply line through the Romex Connector and into electronic control junction box. 3. Connect the white to white; black to black; and green to green or bare copper wire using appropriate sized twist wire connectors.
  • Page 14 CCC Ducted Installation Instructions 9. INSTALLATION OF AIR CONDITIONER Installing unit with 3308120.XXX genesis Air Filtra- Installing unit with 3105007.XXX or 3105935.XXX Re- tion System. turn Air Cover A. INSTALLATION OF FOAM DIVIDER A. INSTALLATION OF CEILINg TEMPLATE 1. Check gasket alignment of the air conditioner over the roof opening and adjust if necessary.
  • Page 15 CCC Ducted Installation Instructions Installing unit with 3308120.XXX genesis Air Filtration Installing unit with 3105007.XXX or 3105935.XXX Re- System, continued from page 13, column B. turn Air Cover, continued from page 13, column A. 2. Install electronic control box on ceiling template 6.
  • Page 16 CCC Ducted Installation Instructions Installing unit with 3105007.XXX or 3105935.XXX Installing unit with 3308120.XXX genesis Air Filtration Return Air Cover, continued from page 14, column A. System, continued from page 14, column B. 3. Place divider plate up to bottom of air conditioner 4.
  • Page 17 CCC Ducted Installation Instructions Installing unit with 3308120.XXX genesis Air Filtration Installing unit with 3105007.XXX or 3105935.XXX System, continued on page 16, column B. Return Air Cover, continued from page 15, column A. Installing unit with 3308120.XXX genesis Air Filtration 7.
  • Page 18: System Configuration, Reset & Checkout

    CCC Ducted Installation Instructions 10. SYSTEM CONFIgURATION, RESET & CHECkOUT A. ELECTRONIC CONTROL CONFIgURATION Depending on the equipment options installed by the recreational vehicle manufacturer, the appropriate dip switches will need to be switched to the "ON" position. See Fig. 20 & 21. Placing the switch in the "ON" position selects that option. Note: Dip switches are in the "OFF"...
  • Page 19: Electronic Field Wiring Diagram

    CCC Ducted Installation Instructions ELECTRONIC FIELD WIRINg DIAgRAM UNIT FIELD WIRINg DIAgRAM (A/C) HEAT PUMP FIELD WIRINg Penguin Brisk Air...

Table of Contents