Dometic Duo-Therm 57915.331 Installation Instructions Manual

Dometic Duo-Therm 57915.331 Installation Instructions Manual

579/595 series brisk air, quick cool roof top air conditioners used with cooling & furnace, cooling, furnace & heat strip remote comfort control kit ducted

Advertisement

USA
SERVICE OFFICE
Dometic Corp.
509 So. Poplar St.
LaGrange, IN 46761
260- 463-4858
CANADA
Dometic Dist.
866 Langs Dr.
Cambridge, Ontario
CANADA N3H 2N7
519-653-4390
For Service Center
Assistance Call:
800-544-4881
This manual must be read and un-
derstood before installation, adjust-
ment, service, or maintenance is
performed. This unit must be in-
stalled by a qualified service tech-
nician. Modification of this product
can be extremely hazardous and
could result in personal injury or
property damage.
C
US
INSTALLATION
INSTRUCTIONS
REVISION:
Form No. 3308489.024 3/04
(Replaces 3308489.016)
(French 3308490.022)
©2004 Dometic Corporation
LaGrange, IN 46761
579 Series BRISK AIR
595 Series QUICK COOL
Roof Top Air Conditioners
3308417.009 Cooling & Furnace
3308417.025 Cooling, Furnace & Heat Strip
Remote Comfort Control Kit
THIS UNIT IS DESIGNED FOR OEM INSTALLATION
ALL INITIAL INSTALLATIONS MUST BE APPROVED BY THE DOMETIC CORP.
!
Important:
Used With
Ducted
!
Lire et comprendre ce manuel avant de
procéder à l'installation, à des réglages,
de l'entretien ou des réparations.
L'installation de cet appareil doit être
effectuée par un réparateur qualifié.
Toute modification de cet appareil peut
être extrêmement dangereuse et
entraîner des blessures ou dommages
matériels.
57915.331
57915.336
57915.531
57915.536
57915.541
57915.546
57915.631
These instructions must stay with
unit. Owner read carefully.
1
579 & 595 Installation Instructions
RECORD THIS UNIT INFORMATION FOR
FUTURE REFERENCE:
Model Number
Serial Number
Date Purchased
MODELS
57915.731
59516.331
59516.336
59516.531
59516.536
59516.631

Advertisement

Table of Contents
loading

Summary of Contents for Dometic Duo-Therm 57915.331

  • Page 1 Ducted Dometic Dist. 866 Langs Dr. THIS UNIT IS DESIGNED FOR OEM INSTALLATION Cambridge, Ontario ALL INITIAL INSTALLATIONS MUST BE APPROVED BY THE DOMETIC CORP. CANADA N3H 2N7 519-653-4390 For Service Center Assistance Call: Lire et comprendre ce manuel avant de...
  • Page 2: Features

    579 & 595 Installation Instructions GENERAL INFORMATION SAFETY INSTRUCTIONS A. Product features or specifications as described or illus- trated are subject to change without notice. This manual has safety information and instruc- B. This air conditioner is designed for: tions to help users eliminate or reduce the risk of 1.
  • Page 3: Specifications

    For wire lengths over 24 ft. consult the National Electric Code for proper sizing. Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications When sizing the generator, the total power usage of your recreational vehicle must be considered. Keep in mind generators lose power at high altitudes and from lack of maintenance.
  • Page 4: Choosing Proper Location For The Air Conditioner

    FIG. 2 2. Dometic Corporation will not be liable for any damages or injury incurred due to failure in It is preferred that the air conditioner be installed on a following these instructions.
  • Page 5: Roof Preparation

    1. Opening Requirements - Before preparing the ceil- ing opening, the type of system options must be decided upon. If a furnace is to be connected, wires must be run from the furnace to the Dometic A/C. Do Not Cut Good-Rafters...
  • Page 6: Air Distribution

    Dometic Corpo- e. Return air to the air conditioner must be filtered ration will not be liable for roof structural or to prevent dirt accumulation on air conditioner cooling surface.
  • Page 7 RECEIVER CCC, CONTROL CABLE(S) LOW VOLTAGE WIRES: 12VDC or 7-Wire Analog Cable CABLE based upon the use of Dometic Return Air Kits 3105007 Furnace Load Shed Return Air Cover, 3105935 Quick Cool Return Air Cover Sensors SIDE VIEW or 3308120 Genesis Air Filtration System. The...
  • Page 8: Wiring Requirements

    The following receiver location is recommended to maintain the selected temperature setting. Any other location must be approved by Dometic. See FIG. 9. 1. Locate the receiver in a front to rear position on the ceiling, and to one side or the other of the return air cover.
  • Page 9: Air Conditioner

    If another receiver mounting location is antici- Important: RJ-11 connectors must be installed as pated, observe the following general rules in determining the location and submit location to Dometic for approval. FIG. 10A • Locate the Receiver 54" above the floor. •...
  • Page 10: Installing Air Conditioner

    FIG. 13 plastic bag. Be sure to place this information in the Divider Plate Please Return to FIG. 11 Dometic All Return- able Cartons Or Recycle All Card- Ceiling Template Return Air board Cartons...
  • Page 11 579 & 595 Installation Instructions faces the rear of the RV. FIG. 15 Control Box • Start each mounting bolt through the ceil- Blunt Point ing template and up into the unit base pan Screws by hand. Install wood screw in each end of the ceiling template.
  • Page 12 579 & 595 Installation Instructions tape located on ceiling template. See FIG. 18. c. Place divider plate up to bottom of air condi- Installing unit with 3308120 Genesis Air Filtration tioner base pan firmly. The foam tape on the System Return Air Kit. For unit with 3105007 or divider plate must seal to bottom of base pan.
  • Page 13 579 & 595 Installation Instructions tion. See FIG. 23 Foam Divider FIG. 26 Snap freeze control into place on return bend located at left (curb side) side of evaporator coil Adhesive as follows: Locate “D” shaped notch in flange of evaporator coil.
  • Page 14: Wiring The System

    579 & 595 Installation Instructions 1/2" this will be a torque of 40 - 50 inch pounds. a. Connect the previously run 12 VDC to the red 5. Use Aluminum foil tape (not supplied) to seal the and black wires protruding from the units return ends of the foam divider to the sides of the opening.
  • Page 15 579 & 595 Installation Instructions Installing unit with 3308120 Genesis Air Filtration System Return Air Kit. For 3105007 or 3105935 Re- turn Air Kit See Page 15. This product is equipped with a 3-wire Note: On models equipped with a solar panel, see wiring (grounded) system for protection against instructions for the solar panel before proceeding.
  • Page 16 J. CONFIGURATION OF REMOTE at the receiver and press the reset button. The Hand Held Remote when shipped from Dometic is al- ways programmed as a cool/furnace model. The dip switches are located in the hand held remote battery compartment.
  • Page 17: Field Wiring Diagram

    579 & 595 Installation Instructions 3308417.009 FIELD WIRING DIAGRAM 509 S. POPLAR ST. FIELD WIRING LAGRANGE, IN 46761 LINE SPLICE 115VAC, 60Hz, 1 O PART No. 3308448.004 TO INFRARED AUX. RECEIVER IF USED FOR USE WITH AIR CONDITIONER: 12 VDC 579, 595 115 VAC, 60 HZ, 1 O USE COPPER...
  • Page 18 !" #$% & &...

Table of Contents