This unit can be installed by one person with brief help from additional personnel. Use these instructions to ensure a properly installed, and properly functioning product. Dometic Corporation reserves the right to modify appearances and specifications without notice. TABLE OF CONTENTS INTRODUCTION ..................................2...
● This product MUST be [installed / serviced] by a qualified service technician. ● Do NOT modify this product in any way. Modifica- tion can be extremely hazardous. ● Do NOT add any devices or accessories to this product except those specifically authorized in writing by Dometic Corporation.
For wire length over 24 ft., consult the National Electrical Code for proper sizing. ** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered.
INSTALLATION INSTRUCTIONS Choosing Proper Location For Unit Dimensions Are Nominal FIG. 1 Model 457915 This unit is specifically designed for installation on the roof 459516 of a recreational vehicle (RV). When determining your cooling requirements, the following should be considered: 13-1/8″...
INSTALLATION INSTRUCTIONS FIG. 3 Dimensions Are Nominal FIG. 5 Model B57915 21-1/8″ B59516 23-1/8″ 2-5/8″ 12-7/8″ 27-5/8″ Dimensions Are Nominal 29-5/8″ 18″ Roof Opening 11-9/16″ 11-9/16″ Center Line Of Unit 3-7/16″ Front Roof Opening 21-1/8″ Keep This Area Free Of Obstructions 3-7/16″...
INSTALLATION INSTRUCTIONS Wiring Requirements d. If the opening exceeds 14-3/8″ x 14-3/8″, it will be necessary to re-size the opening. See 1. Route a copper, with ground, 120 Vac supply "B. Roof Requirements" on page (4). wire from the time delay fuse or circuit breaker e.
INSTALLATION INSTRUCTIONS T his completes the outside work. Minor FIG. 10 adjustments can be done from inside the RV if required. Installing Unit 1. C heck gasket alignment of the unit over the roof opening and adjust if necessary. Unit may be moved from below by slightly lifting.
Page 9
Mounting Bolt Mounting Bolt Pattern Table (See Fig. 15) 120 Vac Model Bolt Location Power Supply 457915 A, D, E & H B57915 A, D, E & H 459516 A, D, E & H b. Route the previously run 120 Vac power sup- B59516 A, D, E &...
INSTALLATION INSTRUCTIONS Wiring System FIG. 18 Ceiling Template 1. 120 Vac Power Supply Connection Alignment a. ELECTRICAL SHOCK HAZ- ARD. Verify 120 Vac power is disconnected from RV. Failure to obey this warning could result in death or serious injury. b.
Page 11
INSTALLATION INSTRUCTIONS 2. Install two (2) (supplied) sheet metal screws in- FIG. 22 side return air opening to secure air distribution box to ceiling template. See (FIG. 20). 3. Install eight (8) (supplied) wood screws inside Slot In ADB the front, rear and side doors to secure air distri- bution box to ceiling.
OPERATING INSTRUCTIONS Controls Heating Operation (With Electric Heater Option Installed). 1. The Selector Switch has (8) positions including "OFF". This controls fan speed, optional heating T he heat mode of operation will NOT replace mode, and cooling modes. See (FIG. 24). a furnace for heating your RV in cold weath- er.
For a more permanent solution to high heat gain, acces- filter removed. If this should occur, inspect the sories like Dometic outdoor patio and window awnings will filter and clean if dirty. Make sure air vents are reduce heat gain by removing the direct sun. They also add open and not obstructed.
● Air distribution box model and serial number found on rating plated located on ceiling tem- plate. Observe this rating plate through the filter opening. WIRING DIAGRAMS Unit Wiring Diagram 2. 540315 & 540316 1. 457915, 459516 B57915 & B59516...