B. A dedicated outlet receptacle for unit should be
located in the side wall of vehicle beneath the
fl anged surface inlet.
C. A cord set fabricated from an oil, water, and ozone
resistant material, such as Type SJOW-A, shall be
used to connect the fl anged surface inlet and the
air conditioning receptacle. This cord set shall be
visible during use and shall not be installed in race-
ways or placed behind walls or cabinet panels.
9. OPERATING INSTRUCTIONS
A. CONTROLS:
1. The Selector Switch has eight positions includ-
ing "OFF". This controls fan speed, heating
mode, and cooling modes. See FIG. 12
FIG. 12
2. The Thermostat controls the temperature range
o
from 65
F on the coldest side to 90
warmest side. In the cooling mode, the com-
pressor ON/OFF controlled by the thermostat
setting. See FIG. 12.
B. COOLING OPERATION:
1. Set the thermostat at the desired temperature
level.
2. Select the fan speed that best satisfi es your
needs:
a. HIGH COOL: Selected when maximum
cooling and dehumidifi cation required.
b. MED. COOL: Selected when normal or
average cooling required.
c. LOW COOL: Selected when room at
desired comfort level and needs to be
maintained. Normally this speed used for
night time operation.
Note: The blower runs continuously to circulate air and
maintain an even temperature. The compressor will come
on as cooling is required to maintain the selected tem-
perature level.
Important:
When the unit is turned on and the ther-
mostat calls for cooling, the compressor will start. After
shutting the unit down manually by either the selec-
tor switch or the thermostat, always wait 2-3 minutes
befor turning on the unit. This allows the refrigerant
pressure in the system to equalize so the compressor
may restart.

CONTROL PANEL

Selector Switch
Note: Never run the unit without return air fi lter in place.
o
F on the
This may plug the unit evaporator coil with dirt and may
substantially affect the performance of the unit.
7
59530 SERIES INSTALLATION AND OPERATING INSTRUCTIONS
C. FAN OPERATION:
1. Turn the selector switch to "FAN ". This will
circulate the air in your RV without cooling or
heating.
2. There are three positions to select from, de-
pending upon personal choice.
a. HIGH FAN
b. MED. FAN
a. LOW FAN
D. "OFF" POSITION:
1. This is to turn Unit off.
E. MAINTENANCE
1. Air Filter
Periodically remove the return air fi lter located
above the removable panel in the air box.
Wash the fi lter with soap and warm water, let
dry and then reinstall.
Thermostat
2. Air Box Housing:
Clean air box housing and control panel with
a soft cloth dampened with a mild detergent.
Never use furniture polish or scouring pow-
ders.
3. Fan Motor:
Factory lubricated and requires no service
under normal use.
4. Frost Formation On Cooling Coil:
Under certain conditions, frost may form on the
evaporator coil. If this should occur, inspect
the fi lter and clean if dirty. Make sure air lou-
vers are not obstructed. Units have a greater
tendency to frost when the outside tempera-
ture is relatively low. This may be prevented
by adjusting the thermostat control knob to a
warmer setting (counter clockwise). Should
frosting continue, operate on LOW, MED. or
HIGH FAN setting until the cooling coil is free
of frost.
F. SERVICE
If your unit fails to operate or operated improperly,
check the following before calling your service
center.