Advertisement

USA
SERVICE OFFICE
Dometic Corporation
509 South Poplar St.
LaGrange, IN 46761
260-463-4858
CANADA
Dometic Distribution
866 Langs Drive
Cambridge, Ontario
CANADA N3H 2N7
519-653-4390
For Service Center
This manual must be read and un-
Assistance Call:
derstood before installation, adjust-
800-544-4881
ment, service, or maintenance is
performed. This unit must be in-
stalled by a qualified service tech-
nician. Modification of this product
can be extremely hazardous and
could result in personal injury or
property damage.
C
US
INSTALLATION
INSTRUCTIONS
REVISION
Form No. 3109270.060 11/03
(Replaces 3109270.052)
(French 3109537.055)
©2003 Dometic Corporation
LaGrange, IN 46761
INSTALLATION INSTRUCTIONS DUCTED CCC
579 Series BRISK AIR
590 Series BRISK AIR
591 Series HEAT PUMP
595 Series QUICK COOL
600 Series PENGUIN
630 Series PENGUIN
Roof Top Air Conditioners & Heat Pumps
Used With Part No. 3109226.005 & 3109407.001
Comfort Control Center Electronic Control Kit
THIS UNIT IS DESIGNED FOR OEM INSTALLATION
ALL INITIAL INSTALLATIONS MUST BE APPROVED BY THE DOMETIC CORP.
WARNING
!
Important:
These instructions must stay with
Ducted
Lire et comprendre ce manuel avant de
procéder à l'installation, à des réglages,
de l'entretien ou des réparations.
L'installation de cet appareil doit être
effectuée par un réparateur qualifié.
Toute modification de cet appareil peut
être extrêmement dangereuse et
entraîner des blessures ou dommages
matériels.
57908.321
57915.531
57908.521
57915.536
57912.621
57915.541
57912.622
57915.546
57912.631
57915.621
57915.322
57915.622
57915.331
57915.631
57915.421
59016.621
57915.422
59136.321
57915.521
59136.331
57915.522
59136.521
unit. Owner read carefully.
1
RECORD THIS UNIT INFORMATION FOR
FUTURE REFERENCE:
Model Number
Serial Number
Date Purchased
!
AVERTISSEMENT
MODELS
59136.531
59516.603
59136.536
59516.631
59136.621
59528.601
59136.631
59529.531
59516.303
59529.601
59516.331
59529.631
59516.336
59530.531
59516.501
59530.532
59516.531
59530.536
59516.536
59530.601
59516.601
59530.631
59530.632
600312.321
600315.326
600312.421
600315.321
600315.421
630035.321
630035.421

Advertisement

Table of Contents
loading

Summary of Contents for Dometic 57908.321

  • Page 1 Comfort Control Center Electronic Control Kit Ducted CANADA THIS UNIT IS DESIGNED FOR OEM INSTALLATION Dometic Distribution 866 Langs Drive ALL INITIAL INSTALLATIONS MUST BE APPROVED BY THE DOMETIC CORP. Cambridge, Ontario CANADA N3H 2N7 AVERTISSEMENT WARNING 519-653-4390 For Service Center...
  • Page 2: General Information

    INSTALLATION INSTRUCTIONS DUCTED CCC 1. GENERAL INFORMATION SAFETY INSTRUCTIONS A. Product features or specifications as described or illus- trated are subject to change without notice. This manual has safety information and instruc- B. This air conditioner is designed for: tions to help users eliminate or reduce the risk of 1.
  • Page 3 INSTALLATION INSTRUCTIONS DUCTED CCC...
  • Page 4 INSTALLATION INSTRUCTIONS DUCTED CCC...
  • Page 5 Up to an 8° slant to either side or front-to-back is B. Dometic Corporation will not be liable for any dam- acceptable on 600 and 630 Series Air Condition- ages or injury incurred due to failure in following these ers/heat pump.
  • Page 6: Air Distribution System

    CAUTION It is the responsibility of the installer to in- sure the ductwork will not collapse or bend during and after the installation. Dometic Corporation will not be liable for roof struc- tural or ceiling damage due to improperly in- sulated, sealed or collapsed ductwork.
  • Page 7 5. AIR DISTRIBUTION SYSTEM INSTALLATION A. Dometic Corporation recommends the basic configuration shown on page 8 for installing this air conditioner/heat pump system. We have found through testing that this configuration works best in most applications of this air conditioner/heat pump system.
  • Page 8 INSTALLATION INSTRUCTIONS DUCTED CCC C. AIR DISTRIBUTION DUCT INSTALLATION 1. Install the Air Distribution Ducts in the RV Roof Cavity. The Distribution System must meet: a. RV’s requirements b. System requirements listed in Section 4 on page 6 of this Manual. Terminate the start of the Duct at the back edge of the 14-1/4"...
  • Page 9 INSTALLATION INSTRUCTIONS DUCTED CCC 6. COMFORT CONTROL CENTER , REMOTE SENSOR & CABLE INSTALLATION A. LOCATION FOR COMFORT CONTROL CENTER AND REMOTE TEMPERATURE SENSOR The proper location of the Comfort Control Center (CCC) is very important to ensure that it will provide a comfortable RV temperature.
  • Page 10 BREAKER BOX BREAKER BOX 2 WIRES 2 WIRES 4-CONDUCTOR 4-CONDUCTOR CONTROL CABLE CONTROL CABLE OPTIONAL OPTIONAL FURNACE FURNACE DOMETIC COMFORT DOMETIC COMFORT CONTROL CENTER CONTROL CENTER FURNACE FURNACE FURNACE 2 WIRES 2 WIRES 14-1/4" x 14-1/4" 14-1/4" x 14-1/4" (±1/8”) OPENING (±1/8”) OPENING...
  • Page 11 INSTALLATION INSTRUCTIONS DUCTED CCC 8. INSTALLATION OF COLD CONTROL A. 579, 590, 591 AND 595 SERIES 1. Insert the Freeze Control Sensor approximately 1" into the fins of the evaporator coil as shown in FIG. 9. Bend fins over sensor to secure in place. 2.
  • Page 12 INSTALLATION INSTRUCTIONS DUCTED CCC 2. Route the previously run AC power supply line through the Romex Connector and into relay control junction box. 3. Connect the white to white; black to black; and green to green or bare copper wire using appropriate sized twist wire connectors.
  • Page 13 INSTALLATION INSTRUCTIONS DUCTED CCC 9. INSTALLATION OF AIR CONDITIONER Installing unit with 3105007.XXX or 3105935.XXX Installing unit with 3308120.XXX Genesis Air Filtra- Return Air Cover tion System. A. INSTALLATION OF CEILING TEMPLATE A. INSTALLATION OF FOAM DIVIDER 1. Locate the foam divider and insert it corner to cor- FIG.
  • Page 14 INSTALLATION INSTRUCTIONS DUCTED CCC Installing unit with 3308120.XXX Genesis Air Filtration Installing unit with 3105007.XXX or 3105935.XXX Re- System, continued from page 13, column B. turn Air Cover, continued from page 13, column A. 2. Install relay control box on ceiling template with 6.
  • Page 15 INSTALLATION INSTRUCTIONS DUCTED CCC Installing unit with 3105007.XXX or 3105935.XXX Installing unit with 3308120.XXX Genesis Air Filtration Return Air Cover, continued from page 14, column A. System, continued from page 14, column B. 3. Place divider plate up to bottom of air conditioner 4.
  • Page 16 INSTALLATION INSTRUCTIONS DUCTED CCC Installing unit with 3308120.XXX Genesis Air Filtration Installing unit with 3105007.XXX or 3105935.XXX Return Air Cover, continued from page 15, column A. System, continued from page 15, column B. 7. Position the relay control box on the tabs of the 2.
  • Page 17 INSTALLATION INSTRUCTIONS DUCTED CCC 10. SYSTEM CONFIGURATION, RESET & CHECKOUT A. ELECTRONIC CONTROL CONFIGURATION Depending on the equipment options installed by the recreational vehicle manufacturer, the appropriate dip switches will need to be switched to the "ON" position. See Fig. 20. Placing the switch in the "ON" position selects that option. Note: Dip switches are in the "OFF"...
  • Page 18 INSTALLATION INSTRUCTIONS DUCTED CCC ELECTRONIC FIELD WIRING DIAGRAM 3106515.020 FIELD WIRING FIELD WIRING -NOT USED ON SOME MODELS -NOT USED ON SOME MODELS 509 S. POPLAR ST. 509 S. POPLAR ST. OPTIONAL WIRING OPTIONAL WIRING -HEATPUMP MODELS ONLY -HEATPUMP MODELS ONLY LAGRANGE, IN 46761 LAGRANGE, IN 46761 FACTORY WIRING...

Table of Contents