The AC version of the IBM
subsystem that provides up to 500-Watt DC with 100–240 VAC input with current and remote
sense regulation. The power subsystem consists of one or two 500-Watt power supply modules. A
system with two modules forms a redundant, hot-swappable (1+1) power subsystem. There is a
single bi-color LED to indicate power supply status. Refer to Table 10 for conditions of the power
supply LEDs.
Table 10.
LED Indicators
Power Supply Condition
No AC power to all PSUs
No AC power to this PSU only
DC present/Only Standby Outputs On
Power supply DC outputs ON and OK
Power Supply in Alert Condition
Power supply failure (OTP, OCP, OVP, UV)
AC Input Voltage Specification
The power supply operates within all specified limits over the voltage ranges outlined in Table 11.
Table 11.
AC Power Supply Input/Output Summary
Voltage
+3.3 VDC Output
+5 VDC Output
+12 V1DC Output
+12 V2DC Output
-12 VDC Output
+5 VDC Standby
Output balancing
AC Line Voltage
AC Line Frequency
AC Input Current
1.
Combined 3.3/5V shall not exceed 120W.
2.
Maximum continuous load on the combined 12V output shall not exceed 25A. Peak load on the combined 12V
output shall not exceed 30A for greater than 10 seconds.
28
®
xSeries 343 server uses an AC input switching power
20 Amp Max 1
20 Amp Max 1
18 Amp Max 2
18.0 Amp Max 2
0.5 Amp Max
2.0 Amp Max
Total combined output power of all output shall not exceed 500 W.
Auto-ranging for either 100-127 VAC or 200-240 VAC
50/60 Hz
4 Amp at 100-127 VAC
2 Amp at 200-240 VAC
Power Supply LED
OFF
AMBER
BLINK GREEN
GREEN
BLINK AMBER
AMBER
Current Rating