Model No.
Nominal
Capacity
(BTU HR)
Cooling
457915.30X
13,500
457915.70X
13,500
459516.30X
15,000
459516.70X
15,000
*
For wire length over 24 ft., consult the National Electric Code for proper sizing.
** Dometic, LLC gives GENERAL guidelines for generator requirements. These guidelines come from experiences people
have had in actual applications. When sizing the generator, the total power usage of your recreational vehicle must be
considered. Keep in mind generators lose power at high altitudes and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or Circuit Breaker Required.

SPECIFICATIONS

Electrical
Compressor
Compressor
Rating
Rated Load
Locked
120 VAC
Amps
Rotor
60Hz. 1PH
Amps
12.4
61.0
12.4
63.0
13.4
64.0
13.3
66.0
Fan Motor
Fan Motor
Refrigerant
Rated Load
Locked
R-410A
Amps
Rotor
(Oz.)
Amps
2.5
5.8
20.0
2.5
5.8
18.0
2.0
5.6
27.5
2.0
5.6
27.5
3
Minimum
AC Circuit
Minimum
Wire Size*
Protection
Generator
12 AWG
***Installer
Size**
Copper
Supplied
1 Unit / 2 Units
Up to 24'
20 Amp
3.5 KW / 5.0 KW
20 Amp
3.5 KW / 5.0 KW
20 Amp
3.5 KW / 5.0 KW
20 Amp
3.5 KW / 5.0 KW