5 Specifications
This section provides the electrical specifications by
model.
Nominal
FreshJet
capacity
model
cooling
(BTU HR)
FreshJet3 series
13,500
FJX3473EWHAS
FJX3473EBKAS
15,000
FJX3573EWHAS
FJX3573EBKAS
FJX3573EHPWHAS
4
FJX3573EHPBKAS
4
FreshJet4 series
FJX4373EHEWHASL
Efficiency
FJX4373EHEBKASL
13,500
FJX4473EWHASL
FJX4473EBKASL
15,000
FJX4573EWHASL
FJX4573EBKASL
FJX4573EHPWHASL
4
FJX4573EHPBKASL
4
1
The wiring size indicated is for copper wiring up to 24 ft (7.3 m) in length. For wire lengths over 24 ft (7.3 m), consult the National Electrical Code for proper sizing.
2
Circuit protection: a time delay fuse or circuit breaker is required.
3
Dometic Corporation gives general guidelines for generator requirements. These guidelines come from experiences people have had in actual applications.
When sizing the generator, the total power usage of your RV must be considered. Generators may lose power at high altitudes and from lack of maintenance.
4
This model includes a heat pump.
The FreshJet 4 series have dual high speed fans.
5
8
Electrical
Compressor
rating
amps
Rated
load
115 VAC,
13.0
60 HZ,
1 ph
High
115 VAC,
9.0
60 HZ,
1 ph
13.0
13.0
Rooftop Air Conditioner (Air Distribution Box, Electronic Controls)
Fan motor
Refrigerant
amps (high)
Locked
Rated
Locked
rotor
load
rotor
73.0
3.3
6.9
73.0
2.2,
3.0,
.87
1.8
5
5
Minimum
AC circuit
R-410A
wire size
protection
1
(installer
supplied)
12.7 oz
12 AWG
20 Amp
(376 ml)
13.4 oz
(396 ml)
13.4 oz
12 AWG
15 Amp
(396 ml)
12.7 oz
20 Amp
(376 ml)
13.4 oz
(396 ml)
Minimum
generator
2
size
3
(1 unit/
2 units)
3.5 kW/
5.0 kW
3.5 kW/
5.0 kW
EN