Dometic 641915.30X Installation Instructions Manual
Dometic 641915.30X Installation Instructions Manual

Dometic 641915.30X Installation Instructions Manual

Roof top unit

Advertisement

USA
SERVICE OFFICE
Dometic, LLC
2320 Industrial Parkway
Elkhart, IN 46516
574-294-2511
CANADA
Dometic, LLC
46 Zatonski, Unit 3
Brantford, Ontario
CANADA N3T 5L8
519-720-9578
For Service Center
Assistance Call:
800-544-4881

INSTALLATION INSTRUCTIONS

3314202.000
Form No. 3314202.000 5/11
(French 3314203.000)
©2011 Dometic, LLC
LaGrange, IN 46761
Description
Air Conditioner
Air Conditioner
W/Electric Heat
Heat Pump
This unit is designed for OEM installation. All initial installations must be approved by Dometic, LLC
This manual must be read and
understood before installation,
adjustment, service, or mainte-
nance is performed. This unit must
be installed by a qualified service
technician. Modification of this
product can be extremely hazard-
ous and could result in personal
injury or property damage.
Important:
stay with unit. Owner read carefully.
Roof Top Unit
Model
Use With Return Air Grill
Model
641915
3105007.XXX
3313192.XXX Cool/Furn
641916
OR
3313193.XXX Cool/Furn/HP
3105935.XXX
3313194.XXX Cool/Furn/HS
641935
651915
651916
Lire et comprendre ce manuel avant de
procéder à l'installation, à des réglages,
de l'entretien ou des réparations.
L'installation de ce produit doit être
effectuée par un réparateur qualifié.
Toute modification de ce produit peut
être extrêmement dangereuse et
entraîner des blessures ou dommages
matériels.
These instructions must
RECORD THIS UNIT INFORMATION
FOR FUTURE REFERENCE:
Model Number
Serial Number
Date Purchased
Single Zone
LCD Thermostat
AVERTISSEMENT
!
MODELS
641915.30X
641916.30X
641935.30X
651915.30X
651916.30X

Advertisement

Table of Contents
loading

Summary of Contents for Dometic 641915.30X

  • Page 1: Installation Instructions

    Heat Pump 651915 2320 Industrial Parkway 651916 Elkhart, IN 46516 574-294-2511 This unit is designed for OEM installation. All initial installations must be approved by Dometic, LLC CANADA Dometic, LLC 46 Zatonski, Unit 3 AVERTISSEMENT Brantford, Ontario CANADA N3T 5L8...
  • Page 2: Safety Instructions

    For a more permanent solution to high heat gain, acces- sories like Dometic outdoor patio and window awnings will CAUTION, used with the safe- reduce heat gain by removing the direct sun. They also add ty alert symbol, indicates a hazardous situation a nice area to enjoy company during the cool of the evening.
  • Page 3: Specifications

    For wire length over 24 ft., consult the National Electric Code for proper sizing. ** Dometic, LLC gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications. When sizing the generator, the total power usage of your recreational vehicle must be considered.
  • Page 4 Free Of Obstructions 12" fully before attempting to start this unit installation. 14-1/4" x 14-1/4" 2. Dometic, LLC will not be liable for any damages (± 1/8") Opening or injury incurred due to failure in following these Center Line instructions.
  • Page 5: Roof Preparation

    It is the responsibility of the installer to insure the duct work will not collapse or bend dur- ing and after the installation. Dometic, LLC There may be electrical wiring between the will not be liable for roof structural or ceiling roof and the ceiling.
  • Page 6 Dometic, LLC in writing. The fol- lowing instructions are based upon the use of Return Air Grill Kits 3105007.XXX & 3105935.XXX.
  • Page 7: Wiring Requirements

    E. Wiring Requirements G. Thermostat and Thermostat Cable Instal- 1. Route a copper, with ground, 120 VAC supply lation wire from the time delay fuse or circuit breaker 1. SZLCD Thermostat box to the roof opening. The proper size wire can be determined from chart on page 3.
  • Page 8: Installing The Unit

    H. Placing The Unit On The Roof I. Installing The Unit 1. Check gasket alignment of the unit over the roof opening and adjust if necessary. Unit may be moved from below by slightly lifting. See FIG. 8. Personal injury hazard. This unit weighs ap- proximately 100 pounds.
  • Page 9 7. Start each mounting bolt through the ceiling tem- c. Place divider plate up to bottom of the unit base plate and up into the unit base pan by hand. Install pan firmly. The foam tape on the divider plate wood screw in each end of the ceiling template.
  • Page 10 J. Wiring The System a. Route power supply line through Romex con- nector and into junction box on side away from Reach up into the return air opening and pull the re- the ceiling template. Tighten connector making maining wires down. See FIG. 10. sure not to damage wires.
  • Page 11: Wiring Diagram

    WIRING DIAGRAM 641915 & 641916 Wiring Diagram 641935 Wiring Diagram 651915 & 651916 Wiring Diagram...

Table of Contents