68
IBM TotalStorage DS4300 Fibre Channel Storage Subsystem: Installation, User's, and Maintenance Guide
Fourth storage
expansion enclosure
ESM A
Third storage
expansion enclosure
ESM A
Second storage
expansion enclosure
ESM A
First storage
expansion enclosure
ESM A
Figure 52. Connecting two EXP810 storage expansion enclosures into redundant drive loop
B
If you want to connect more storage expansion enclosures into drive loops A
and B, continue with Step 3; otherwise, go to "Connecting the redundant
EXP810 drive loop to the DS4300" on page 69.
3. Connect additional storage expansion enclosures to drive loops A and B, as
shown in Figure 53 on page 69.
Starting with the second storage expansion enclosure, connect each additional
storage expansion enclosure into drive loops A and B in the same manner.
Leave port 1A on the ESM B of the last (fourth) storage expansion enclosure in
the loop and port 1A on the ESM A of the first storage expansion enclosure
unoccupied.
Port 1B
Port 1A
EXP810
Port 1B
Port 1A
EXP810
Port 1A
Port 1B
Port 1A
EXP810
Port 1A
Port 1B
EXP810
Port 1A
ESM B
Port 1B
ESM B
Port 1B
ESM B
Loop A
Port 1B
ESM B
Loop B
Port 1B
ds4500_8103