IBM xSeries 300 Hardware Maintenance Manual page 73

Hide thumbs Also See for xSeries 300:
Table of Contents

Advertisement

Error Code/Symptom
035-XXX-S99
(Failed RAID test on PCI slot
S. S = number of failing PCI
slot. Check System Error Log
before replacing a FRU.)
035-XXX-SNN
(Check System Error Log
before replacing a FRU. S =
number of failing PCI slot;
NN = SCSI ID of failing fixed
disk.)
035-253-S99
(RAID adapter initialization
failure)
075-XXX-000
(Failed Power Supply test)
089-XXX-001
(Failed Microprocessor test)
180-XXX-003
(Failed System Board LED
test)
201-XXX-0NN
(Failed Memory test) NN =
DIMM location.
201-XXX-999
(Multiple DIMM failure, see
error text.)
202-XXX-001
(Failed System Cache test)
206-XXX-000
(Failed Diskette Drive test)
215-XXX-000
(Failed IDE CD-ROM test)
217-XXX-000
(Failed BIOS Fixed Disk test)
Note: If RAID is configured,
the fixed disk number refers
to the RAID logical array.
FRU/Action
1. Adapter
2. SCSI Backplane
3. Cable
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
1. ServeRAID Adapter in slot S is not configured properly. Obtain the basic and
extended configuration status and refer to the ServeRAID Hardware Maintenance
Manual for more information.
2. Cable
3. Adapter
1. Power Supply
1. Microprocessor
1. System Board
1. DIMM Location J1-J4
2. Memory card
1. See error text for failing DIMMs
1. Microprocessor CPU 1
1. Cable
2. Diskette Drive
3. System Board
1. CD-ROM Drive Cables
2. CD-ROM Drive
3. System Board
1. Fixed Disk 1
Chapter 7. Symptom-to-FRU index