Hardware Maintenance Manual: xSeries 300
Table 4. NDIS (Windows NT or Windows 2000) driver messages for the Ethernet
controller (continued)
Error code
Description
(hex)
0x03
Explanation: Failed self-test. Action: Make sure a cable is attached to the
Ethernet connector.
0x0D
Explanation: Could not allocate enough memory for transmit queues.
Action:
1. From the Windows NT desktop, select Start → Control Panel →
Networks → Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Select Properties → Advanced.
4. Lower the resource values that apply to the transmit queue.
0x0E
Explanation: Could not allocate enough memory for receive queue. Action:
1. From the Windows NT desktop, select Start →Control Panel →Networks
→Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Select Properties →Advanced.
4. Lower the resource values that apply to the receive queue.
0x0F
Explanation: Could not allocate enough memory for other structures.
Action:
1. From the Windows NT desktop, select Start → Control Panel →
Networks → Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Select Properties →Advanced.
4. Lower the value for the resource named in the message.
0x10
Explanation: Did not find any Ethernet controllers. Action: Using the
Configuration/Setup Utility program, make sure that Ethernet is enabled.
0x11
Explanation: Multiple Ethernet controllers found, but none matched the
required ID. Action: Using the Configuration/Setup Utility program, make
sure that Ethernet is enabled.
0x13
Explanation: Did not find any Ethernet controllers that matched the
required subven/subdev. Action: Using the Configuration/Setup Utility
program, make sure that Ethernet is enabled.
0x16
Explanation: Single adapter found, but multiple instances tried to load.
Action: Using the Configuration/Setup Utility program, make sure that
Ethernet is enabled, and that the slot containing the IBM xSeries 200
10/100 Ethernet Adapter or the IBM 10/100 Etherjet PCI adapter is
enabled.
0x17
Explanation: Slot parameter not specified in the registry. Action: Remove
the adapter driver and reinstall it.