How to Operate PU Operation
4.2
How to Operate PU Operation
4.2.1
Normal operation
During motor operation, the speed can be changed
by simply executing Step 2.
Step
Operation Procedure
1
Switch power ON.
Make sure that the monitor
appears.
2
Set the running
frequency.
Set the running frequency
using direct setting or step
setting. (Refer to page 30)
3
Press
or
The motor starts running.
The parameter unit
automatically enters the
monitoring mode and shows
the output frequency.
84
Image
1. Power on
Operation mode check
ON
READ:List
0.00
--- STOP PU
2. Running frequency setting
<Direct setting>
Freq Set
SET
0.00Hz
0~400Hz
.
3. Start
(or)
READ:List
60.00
STF STOP PU
Step
Operation Procedure
4
Press
The motor is decelerated to
a stop.
Hz
REMARKS
·
When performing PU operation to run the motor,
pressing the start key (
running frequency switches to monitor mode
automatically.
·
When FR-PU07BB is used in the battery mode (the
inverter power is OFF), the operation is not available.
Hz
Image
.
4. Stop
or
) after setting the
Stop