Adjustment of the Frequency Setting Signals "Bias" and "Gain"
Setting of the frequency setting voltage gain
6
Press
.
The present setting appears.
7
Enter
.
Voltage need not be applied
across terminals 2-5.
8
Press
.
The bias frequency is set at
50Hz.
At this time, set the gain on
the assumption that the 5V
(10V) in the inverter is the set
voltage.
f
50Hz
10Hz
0
(10V)
The adjustment of the frequency setting voltage
bias and gain is complete.
48
903 Ext2gain
60.00Hz
Set<WRITE>
Ext<READ>
903 Ext2gain
50Hz
Set<WRITE>
903 Ext2gain
50.00Hz
50.00Hz
Completed
V
5V
REMARKS
1
The current input (Pr. 904) can also be adjusted
using a similar procedure.
2
The Pr. 903 Terminal 2 frequency setting gain remains
unchanged if the Pr. 20 Acceleration/deceleration
reference frequency setting is changed.