3-4.

Misfeed at Fusing Unit J3

Exit Paper Sensor (PC3)
Fusing Cooling Fan Motor (M3)
FUSING SECTION
Fusing Cooling
Fan Motor

PAPER EXIT SECTION

Exit Paper
Sensor
Misfeed at Fusing Unit J3 Troubleshooting Procedures
• Paper is at a stop at the Fusing Unit.
Step
1
Fusing guide plate is dirty, scratchy,
deformed, worn, or damaged.
2
Fusing Paper Separator Fingers are
dirty, scratchy, deformed, or worn.
3
Fusing Rollers are dirty, scratchy,
deformed, or worn.
• Paper is at a stop at the paper exit section.
Step
1
Exit guide plate is dirty, scratchy,
deformed, worn, or damaged.
2
Transport Roller is dirty, scratchy,
deformed, or worn.
3
Exit Roller/Rolls are dirty, scratchy,
deformed, or worn.
Relevant Electrical Parts
Check
Check
T-16
Master Board (PWB-A)
PC3 ANODE
PWB-A
Master Board
Result
YES • Clean or change.
YES • Clean or change the Fusing Paper
Separator Fingers, or change
spring.
YES • Clean or change.
Result
YES • Clean or change.
YES • Clean or change.
YES • Clean or change.