5.13 BCD Function Block

Description
The BCD label stands for Binary Coded Decimal Translator. This block is part of the Auxiliary category.
It looks like this graphically on the Control Builder.
Dynamic Parameters:
Parameter
Index
status
0
OUT
1
DIG_A(D1)
2
DIG_B(D2)
3
DIG_C(D4)
4
DIG_D(D8)
5
DIG_E(D10)
6
DIG_F(D20)
7
DIG_G(D40)
8
DIG_H(D80)
9
Static Configuration Parameters: None
8/99

Table 5-16 BCD Dynamic Parameters

Type
Use
R/W
REAL
C
R
REAL
O
W
BOOL
I
R
BOOL
I
R
BOOL
I
R
BOOL
I
R
BOOL
I
R
BOOL
I
R
BOOL
I
R
BOOL
I
R
RS232 Communications Reference Manual
Function Parameter Index Reference
Description
block status (see section 5.2 for code list)
Result (O to 99)
Bit 0 of the BCD lower digit
Bit 1 of the BCD lower digit
Bit 2 of the BCD lower digit
Bit 3 of the BCD lower digit
Bit 0 of the BCD upper digit
Bit 1 of the BCD upper digit
Bit 2 of the BCD upper digit
Bit 3 of the BCD upper digit