Electrical Requirements - Jackson Enodis 300X Technical Manual

Upright door dishmachine series
Table of Contents

Advertisement

NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-trip
circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is dis-
played here. Always verify with your electrical service contractor that your circuit protection is adequate and meets all
applicable national and local codes. These numbers are provided in this manual simply for reference and may change with-
out notice at any given time.
300X
VOLTS
PH
HZ
208
1
50
12 KW@240V 71
208
1
50
14 KW@240V 78
230
1
50
12 KW@240V 78
230
1
50
14 KW@240V 86
208
3
50
12 KW@240V 45
208
3
50
14 KW@240V 49
230
3
50
12 KW@240V 48
230
3
50
14 KW@240V 53
380
3
50
12 KW@380V 29
*380
3
50
14 KW@208V 34
415
3
50
12 KW@415V 26
415
3
50
14 KW@415V 29
440
3
50
12 KW@460V 21
440
3
50
14 KW@460V 25
208
1
60
12 KW@240V 69
208
1
60
14 KW@240V 76
230
1
60
12 KW@240V 76
230
1
60
14 KW@240V 84
208
3
60
12 KW@240V 43
208
3
60
14 KW@240V 47
230
3
60
12 KW@240V 46
230
3
60
14 KW@240V 51
460
3
60
12 KW@480V 22
460
3
60
14 KW@480V 24
300XN
VOLTS
PH
HZ
208
1
50
N/A
230
1
50
N/A
208
3
50
N/A
230
3
50
N/A
380
3
50
N/A
415
3
50
N/A
440
3
50
N/A
208
1
60
N/A
230
1
60
N/A
208
3
60
N/A
230
3
60
N/A
460
3
60
N/A
SECTION 1: SPECIFICATION INFORMATION

ELECTRICAL REQUIREMENTS

RINSE
TYPICAL
HEATER
TOTAL
ELECTRICAL
RATINGS
AMPS
CIRCUIT
90 AMP
100 AMP
100 AMP
110 AMP
60 AMP
70 AMP
60 AMP
70 AMP
40 AMP
45 AMP
35 AMP
40 AMP
30 AMP
35 AMP
90 AMP
100 AMP
100 AMP
110 AMP
60 AMP
60 AMP
60 AMP
70 AMP
30 AMP
30 AMP
RINSE
TYPICAL
HEATER
TOTAL
ELECTRICAL
RATINGS
AMPS
CIRCUIT
28
35 AMP
30
40 AMP
20
25 AMP
21
30 AMP
10
15 AMP
10
15 AMP
8
15 AMP
26
35 AMP
28
35 AMP
18
25 AMP
28
35 AMP
8
15 AMP
300X Series Technical Manual 7610-002-64-22
Issued: 07-26-2006 Revised: N/A
300XLT
RINSE
HEATER
VOLTS
PH
HZ
208
1
50
N/A
230
1
50
N/A
208
3
50
N/A
230
3
50
N/A
380
3
50
N/A
415
3
50
N/A
440
3
50
N/A
208
1
60
N/A
230
1
60
N/A
208
3
60
N/A
230
3
60
N/A
460
3
60
N/A
300XS
RINSE
HEATER
VOLTS
PH
HZ
208
1
50
N/A
230
1
50
N/A
208
3
50
N/A
230
3
50
N/A
380
3
50
N/A
208
1
60
N/A
230
1
60
N/A
208
3
60
N/A
230
3
60
N/A
460
3
60
N/A
* This unit is wired in a wye configuration for the heaters.
3
TYPICAL
TOTAL
ELECTRICAL
RATINGS
AMPS
CIRCUIT
28
35 AMP
30
40 AMP
20
25 AMP
21
30 AMP
10
15 AMP
10
15 AMP
8
15 AMP
26
35 AMP
28
35 AMP
18
25 AMP
28
35 AMP
8
15 AMP
TYPICAL
TOTAL
ELECTRICAL
RATINGS
AMPS
CIRCUIT
7
15 AMP
7
15 AMP
7
15 AMP
7
15 AMP
7
15 AMP
6
15 AMP
6
15 AMP
6
15 AMP
6
15 AMP
2
15 AMP