Electrical Requirements - Jackson TEMPSTAR Series Installation, Operation & Service Manual

Upright door dishmachines
Table of Contents

Advertisement

NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical
fixedtrip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection
than what is displayed here. Always verify with your electrical service contractor that your circuit protection is
adequate and meets all applicable national and local codes. These numbers are provided in this manual simply
for reference and may change without notice at any given time.
TEMPSTAR HH:
Volts
415
415
208
208
230
230
208
208
230
230
460
460
TEMPSTAR HH NB & TEMPSTAR HH LT:
Volts
208
230
208
230
460
TEMPSTAR HH S:
Volts
208
230
208
230
Phase
Freq
3
60
3
60
1
60
1
60
1
60
1
60
3
60
3
60
3
60
3
60
3
60
3
60
Phase
Freq
1
60
1
60
3
60
3
60
3
60
Phase
Freq
1
60
1
60
3
60
3
60

ELECTRICAL REQUIREMENTS

Rinse Heater
Ratings
12kW
14kW
12kW@240V
12kW@240V
12kW@240V
14kW@240V
12kW@240V
14kW@240V
12kW@240V
14kW@240V
12kW@480V
14kW@480V
Rinse Heater
Ratings
N/A
N/A
N/A
N/A
N/A
Rinse Heater
Ratings
N/A
N/A
N/A
N/A
3
SPECIFICATIONS
Typical Electrical
Total Amps
Circuit
28A
35AMP
30A
40AMP
75A
100AMP
82A
110AMP
81A
110AMP
90A
125AMP
48A
60AMP
52A
70AMP
52A
70AMP
57A
80AMP
24A
30AMP
26A
35AMP
Typical Electrical
Total Amps
Circuit
31A
35AMP
33A
35AMP
23A
25AMP
24A
35AMP
10A
15AMP
Typical Electrical
Total Amps
Circuit
12A
15AMP
12A
15AMP
12A
15AMP
12A
15AMP