Fan And Communications Module Ports And Indicator Light; Removing And Installing A Fan And Communications Module - IBM TotalStorageFAStT900 User Manual

Fibre channel storage server
Table of Contents

Advertisement

1. Disconnect all Ethernet interface cables from the failed fan and communications
module. The locations of the ports are shown in the following figure.
Figure 42. Fan and communications module ports and indicator light
2. Use Figure 43 as a guide and perform the following steps to remove the failed
fan and communications module from the FAStT900 Storage Server.
Figure 43. Removing and installing a fan and communications module
a. Using a flat-blade screwdriver, loosen the two captive screws on the fan and
communications module.
b. Use the pull handle to slide the module out of the slot a few inches.
c. Grasp the sides of the module with both hands and remove it from the
FAStT900 Storage Server.
Chapter 3. Replacing the FAStT900 Storage Server components
49