4. INSTALLATION
Connection of WAGO connector
Remove the WAGO connector from each unit and connect each cable core to the
WAGO connector. See the interconnection diagram (page S-1). The terminal opener
is attached inside the remote display at the location shown in the illustration below.
Cable entrance
4-14
WAGO connector
Remote display, rear panel
How to connect wires to WAGO connector
Press downward.
Wire
Twist
Procedure
1. Twist the cores.
2. Press the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that it is secure.
Fuse
Terminal opener
Ground terminal
Terminal opener
WAGO connector