2) For the power cable, unfasten the clamping gland and remove washers and
gasket from the DS-605. Discard the washers and gasket. Pass the clamping
gland, washer (26-003-1607), gasket (26-003-1605) and washer (supplied as
installation materials) onto the power cable, in that order.
Note: Do not use the washers and gasket which are removed from the cable
gland of the DS-605.
3) For the sensor signal cable, unfasten the clamping gland and remove wash-
ers and gasket from the DS-605. Pass the clamping gland, washer, gasket and
washer onto the the sensor signal cable, in that order.
4) Pass each cable through assigned cable gland.
*: Installation
materials
Gasket*
Clamping
gland
5) Put the flush mounting sponge to the flange from the rear side of the RD-50.
6) Open the front cover of the DS-605 and connect the ground wire attached in-
side the DS-605 to the ground terminal on the rear of the RD-50.
7) Connect the cables to the RD-50. Refer to section 4.5.
3. Remove each binding head screw from four corners of the DS-605 and set the
RD-50 to the DS-605.
4. Apply silicon grease to the binding head screws and fix the RD-50 to the DS-605
with four binding head screws.
5. Tighten the clamping glands to fix the cables.
6. Apply the putty to the cable glands for waterproofing.
7. Connect the ground terminal for the DS-605 to the ground terminal on the hull with
the IV-1.25 sq wire.
Washer*
{
Gasket**
Sensor signal cable
Power cable
4. INSTALLATION