Unit Assembly Prior To Installation; Flueing Introduction - Regency P36-NG5 Owners & Installation Manual

Gas log fireplace
Table of Contents

Advertisement

UNIT ASSEMBLY
PRIOR TO
INSTALLATION
The Top Facing Support, the Side Nailing Strips
and the 2 Top Standoffs must be correctly
positioned and attached to the top before unit
is slipped into position.
Top Standoff Assembly
The top standoffs are shipped in a fl at position
and must be folded into shape and attached.
1) Remove the standoffs from the fi replace
top.
2) Take each standoff and bend into the correct
shape. Bend up at the bend lines until the
screw holes in the standoff and the pre-
punched screw holes on the fi replace top
line up.
3) Attach the standoff securely to the top with 2
screws per standoff (on opposite corners).
Top Facing Support and
Side Nailing Strips
Determine the total thickness of facing material
(e.g. drywall plus ceramic tiles) to allow the
fi nished surface to be fl ush with the front of the
unit. Total facing thickness can vary from 1/2"
(13mm) to 1-1/4" (32mm) thick.
The Top Facing Support & Side Nailing Strips can
be mounted in 3 different positions depending
on the thickness of the facing material.
Screw
Facing Material
Position
Depth
A
1/2"
/ 13mm
B
7/8"
/ 22mm
C*
1-1/4"
/ 32mm
* For "C" screw position the top facing support
is reversed.
Regency
P36-5 Gas Log Fireplace
®
1) Mount Top Facing Support using the 3
supplied screws into the three pre-punched
screw holes on the top front of the unit. Use
hole positions A, B, or C depending on your
facing depth.
"C" Screw Position:
For a facing material depth of 1-1/4"
(32mm), the top facing support must be
reversed.
2) Use the same screw hole position for the
Side Nailing Strips as was used for the Top
Facing Support. Attach each side nailing
strip using 3 screws.
INSTALLATION
Premium Flush Front
Spacer Installation
Before the unit is slid into position, install the
provided spacers to the side of the fi replace
as follows;
1) Align the screw locations on spacer with
screw locations on the side of the fi rebox
and secure in place using 3 screws.
2) Repeat for other side.
NOTE: The side nailing strips are to be in-
stalled to the spacer after the spacer
is attached to the unit.
Spacer
Left Side Shown
FLUEING
INTRODUCTION
The P36 uses the "balanced fl ue" technology
Co Axial system. The inner liner fl ues products
of combustion to the outside while the outer
liner draws outside combustion air into the
combustion chamber thereby eliminating the
need to use heated room air for combustion and
losing warm room air up the chimney.
Note:
These flue pipes must not be
connected to any other appliance.
The gas appliance and fl ue system must be
fl ued directly to the outside of the building,
and never be attached to a chimney serving a
separate solid fuel or gas burning appliance.
Each Co Axial Flue gas appliance must use
it's own separate fl ue system. Common fl ue
systems are prohibited.
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

P36-lpg5

Table of Contents