IMPORTANT MESSAGE

SAVE THESE INSTRUCTIONS
The P36-NG or P36-LPG Room Sealed Fireplace
must be installed in accordance with AS5601-
2004 and NZS 5261 5261 and these instructions.
Carefully read all the instructions in this manual
fi rst. Consult the "authority having jurisdiction"
to determine the need for a permit prior to
starting the installation. It is the responsibility of
the installer to ensure this fi replace is installed
in compliance with manufacturer's instructions
and all applicable codes.

BEFORE YOU START

NOTE: NOT INTENDED AS A FIREPLACE
INSERT.
INSTALLATION AND REPAIR SHOULD
BE DONE BY A AUTHORISED SERVICE
PERSON. THE APPLIANCE SHOULD BE
INSPECTED BEFORE USE AND AT LEAST
ANNUALLY BY AN AUTHORISED SERVICE
PERSON. MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING, BEDDING
MATERIAL, ETC. IT IS IMPERATIVE THAT
CONTROL COMPARTMENTS, BURNERS
AND CIRCULATING AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED OUT
OF TRAFFIC AND AWAY FROM FURNITURE
AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID YOUR
WARRANTY AND MAY CAUSE A SERIOUS
HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES, ESPECIALLY
THE FIREPLACE GLASS, AND SHOULD
STAY AWAY TO AVOID BURNS OR
CLOTHING IGNITION.
Y O U N G C H I L D R E N S H O U L D B E
CAREFULLY SUPERVISED WHEN THEY
ARE IN THE SAME ROOM AS THE
APPLIANCE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED ON
OR NEAR THE APPLIANCE. DO NOT USE
AEROSOLS IN THE VICINITY OF THIS
APPLIANCE.
Regency
P36-5 Gas Log Fireplace
®
GENERAL SAFETY
INFORMATION
1) The appliance shall be installed in
accordance with the manufacturer's
installation instructions,local gas fi tting
regulations, municipal building codes,
water supply regulations, electrical wiring
regulations, with AS5601-2004 (AGA
gas installation code) NZS 5261 (New
Zealand)
2) Installation and repair should be done
ONLY by an authorised person.
3) THIS APPLIANCE IS NOT INTENDED AS A
FIREPLACE INSERT. DO NOT CONNECT
TO MASONARY FLUE.
4) This appliance must be connected to
the specifi ed fl ue and termination cap
to the outside of the building envelope.
Never fl ue to another room or inside a
building. Make sure that the fl ue is fi tted
as per Flueing instructions.
5) Inspect the fl ueing system annually for
blockage and any signs of deterioration.
6) Flueing terminals shall not be recessed into
a wall or siding.
7) Any safety glass removed for servicing
must be replaced prior to operating the
appliance.
8) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fi replace.
9) Wear gloves and safety glasses for protection
while doing required maintenance.
10) Be aware of electrical wiring locations in
walls and ceilings when cutting holes for
termination.
11) Under no circumstances should this
appliance be modifi ed. Parts that have to be
removed for servicing should be replaced
prior to operating this appliance.
12) Installation and any repairs to this appliance
should be done by an authorised service
person. An authorised service person should
be called to inspect this appliance annually.
Make it a practice to have all of your gas
appliances checked annually.
13) Do not slam shut or strike the glass door.
14) Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.)
be used in this appliance.
15) The appliance area must be kept clear and
free of combustible materials, (gases and
other fl ammable vapours and liquids).

INSTALLATION

INSTALLATION
CHECKLIST
1) Locate appliance
a) Locate Your Gas Fireplace
b) Clearances
c) Combustible Mantels
d) Framing & Finishing
2) Assemble Top Standoffs and Top Facing
Support and Side Nailing Strips, refer to
section "Unit Assembly Prior to Installation".
(NOTE: must be done before installing unit
into fi replace.)
3) Install fl ue (Refer to section "Simpson Dura-
vent Flueing").
4) Make gas and electrical connections. Test
the pilot. Must be as per diagram. Refer to
section "Pilot Adjustment."
5) Install standard and optional features. Refer
to the following sections:
a. Brick Panels
b. Log Set
c. Flush Door
d. Premium Flush Front
e. Wall Switch
f. Remote Control
g. Wall Thermostat
6) Final check.
Before leaving this unit with the customer,
the installer must ensure that the appliance is
fi ring correctly and operation fully explained
to customer.
This includes:
1) Clocking the appliance to ensure the correct
fi ring rate (rate noted on label ) after burning
appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.