GE Monogram ZBD6400 Series Technical Service Manual page 23

Hide thumbs Also See for Monogram ZBD6400 Series:
Table of Contents

Advertisement

6000 & 7000 Series DISHWASHERS
4.10.2 TEMPERATURE CALIBRATION TEST
4.10.2.1 Models 6400/6500, 6700/6900, 6905.
During the Relay/Triac output test (Refer 4.10.1) the program and option LEDs form a bar graph display indicating the tem-
perature of the door thermistor. See table below.
Note: A thermistor resistance of 1K7=113 ° F water temperature.
LEGEND:
O = LED OFF
Thermistor Temperature (°F)
6400 / 6500
POTS &
POTS
6700 / 6900
POTS &
POTS
6905
HEAVY
DUTY
34-75 DEG
O
77-93 DEG
O
95-111 DEG
O
113 DEG
O
115-129 DEG
O
131-147 DEG
O
149-165 DEG
O
167-210 DEG
X
An open circuit thermistor or temperature sensed below 32°F - all program and option LEDs are to turn on.
A closed circuit thermistor or temperature sensed above 210°F - all program and option LEDs are to flash at a 0.5 second
on 0.5 second off rate.
4.10.2.2 Models 6600, 6605, and 7000.
During the Relay/Triac output test, (Refer 4.10.1), If the temperature calibration point of 113°F is reached, then Smart Dry LED
will illuminate on 7000 series machines, alternatively the WASH CYCLES LED will illuminate on Rotary machines (provided
Door Thermistor monitoring was selected).
If an open circuit thermistor is detected, (temperature sensed is below 32° F), then the indicator LED will flash at a 1 second on,
1 second off rate.
If a short circuit thermistor is detected, (temperature sensed is above 210° F), then the indicator LED will flash at a 0.5 second
on 0.5 second off rate.
Notes: No other thermistor temperatures are displayed.
A door thermistor resistance of 1K7 W = 113 ° F water temperature.
4.10.3 WATER LEVEL SENSING OPERATION
Models 6400/6500, 6600, 6605, 6700/6900, 6905 ,7000 Series.
During the Relay/Triac output test (Refer 4.10.1) the RINSING LED, (RINSE ONLY LED on 7000 series), (or the WASH
CYCLES LED on Rotary machines, provided Water Level monitoring was selected), will indicate the water level in the
dishwasher.
IF the second level pressure switch, or the under sump switch, activates the drain pump, (i.e.. Overfill detected),
THEN the indicator LED will Flash at 1Hz.
ELSE
IF the Pressure switch circuit is open, (water detected),
THEN the indicator LED will be constantly illuminated.
ELSE
the indicator LED will not be illuminated, (i.e.. Water not detected).
Note: Overfill can not be detected while the drain pump is activated.
X = LED ON
NORMAL
CHINA
WASH
CRYSTAL
NORMAL
CHINA
WASH
CRYSTAL
NORMAL
LIGHT
WASH
WASH
O
O
O
O
O
O
O
O
O
O
O
X
X
X
X
X
SANI
HEATED
WASH
DRY
RINSE
SMART
ONLY
DRY
RINSE
SMART
ONLY
DRY
O
O
O
O
O
X
O
X
X
X
X
X
X
X
X
X
WATER
DELAY
TEMP
START
WATER
DELAY
TEMP
START
WATER
DELAY
TEMP
START
O O O
XX
XXX
XX
XXX
XX
O
O
XXX
XX
XXX
XX
XXX
XX
XXX
XX
PAGE 21