6000 & 7000 Series DISHWASHERS
3.1.2.5 Wash Motor/Pump Assembly
120V AC, 60Hz, 1.7A.
110W, MCR CS&R, 3250 rpm.
Class F
Capacitor 15µF 370V
WARNING: Motor is fitted with internal auto reset overload
and may restart without warning.
Resistance of windings @ 68°F ±5%
Terminals A & C = 11.6 ohms
Terminals B & C = 5.9 ohms
Motor Plug
3.1.3 Switches/thermostats
3.1.3.1 Thermostat - Overtemp
Identification - Blue Dot.
Mounting - Gasket in Tub base.
Electrical connection -1/4" Quick Connect tabs.
125V/250V.
Temperature specification: - Open 185°F ± 38°F.
- Reset 113°F ± 41°F.
3.1.3.2 Switch-Light
All Models except 6400 & 6500
240V/120V AC, 5A.
Circuit - normally Open.
Electrical connection - 2 x 1/4" Quick Connect tabs.
3.1.3.3 Microswitch - Door Lock
General Purpose Type approved by UL.
250/125V AC, 21A.
Pin Plunger Actuator SPST.
Normally open with common terminal at bottom.
Electrical connection - 1/4" Quick Connect tabs.
3.1.3.4 Pressure Switch - Level 1
Main Contact Load - 16A, 240/125V AC.
Electrical connection - 1/4" Quick Connect tabs.
Nominal Calibration - set 2 3/16" water
- reset 19/32" water
Operating Temperature - 185°F maximum.
UL Approved.
3.1.3.5 Pressure Switch - Level 2
Main Contact Load - 16A, 250/125V AC.
Electrical connection - 1/4" Quick Connect tabs.
Nominal Calibration - set 3 13/16" water
- reset 3 1/32" water
Operating Temperature - 185°F maximum.
UL Approved.