GE Monogram ZBD6400 Series Technical Service Manual page 21

Hide thumbs Also See for Monogram ZBD6400 Series:
Table of Contents

Advertisement

6000 & 7000 Series DISHWASHERS
4.10.1 RELAY / TRIAC OUTPUT TEST (LATCHING MODE)
4.10.1.1 Models 6400/6500, 6700/6900, 6905, 7000
By pressing the following button sequence the relay output test mode can be accessed.
6400/6500
#5 Heated Dry
#2 Normal Wash
#4 Sani Wash
#5 Heated Dry
#8 Start Cancel
* Note: For 6700/6900, 6905 and 7000 series:
No beep will be heard when Smart Dry is pressed the second time, as Smart Dry
is not a valid Customer option for a Rinse Only wash that was selected just prior.
Individual outputs can then be energized/de-energized by pressing the corresponding control button.
6400/6500
6700/6900
#1 Pots & Pans
#1 Pots & Pans
#2 Normal Wash #2 Normal Wash
#3 China Crystal #3 China Crystal
#4 Sani Wash
#4 Rinse Only
#5 Heated Dry
#5 Smart Dry
#6 Water Temp
#6 Water Temp
#7 Delay Start
#7 Delay Start
#8 Start Cancel #8 Start Cancel
* 7000 Series note:
There is no Drying LED on the 7000 series. Special attention is required when activating the
heater, to ensure it is not accidentally left on.
The relay / triac output test can be cancelled by, repeating the button sequence shown above, or by removing power.
6700/6900
#5 Smart Dry
#2 Normal Wash
#4 Rinse Only
#5 Smart Dry*
#8 Start Cancel
CONTROL BUTTON
6905
No Turbidity
#1 Pots & Pans
sensor fitted.
#2 Normal Wash
#2 Normal Wash
#3 Light Wash
#3 China Crystal
#4 Rinse Only
#4 Rinse Only
#5 Smart Dry
#6 Smart Dry
#6 Water Temp
#6 Water Temp
#7 Delay Start
#7 Delay
#8 Start Cancel
#8 Start Cancel
6905
7000 Series
#5 Smart Dry
#6 Smart Dry
#2 Normal Wash
#2 Normal Wash
#4 Rinse Only
#4 Rinse Only
#5 Smart Dry*
#6 Smart Dry*
#8 Start Cancel
#8 Start Cancel
OUTPUT CONTROLLED
7000 Series
Turbidity Sensor.
The SENSING LED, (or POTS &
PANS LED on 7000 series), will light
when there are valid turbidity sensor
readings, (Refer 2.6).
Detergent/Rinse Aid Dispenser.
Drain Pump.
Heating Element +
Drying LED*.
Continuously pulses the Heating
element as per the Smart/Heated Dry
– Post Heatup Drying Pulse
specification.
Wash Pump.
Fan Motor.
Fill valve, (limited to 3 minutes o
prevent flooding).
PAGE 19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents