Pluming kit (Fig. 6.11)
Co-axial ø 60/100 mm + vertical part ø 60
mm (flue outlet).
This kit allows the comburent air to be
sucked up and expel the burnt gases di-
rectly to the outside through a telescopic
co- axial flue (450-950 mm).
Type C52
90° =--- 0,85 m
ø 60 mm
45° =--- 0,65 m
Fig. 6.11
In the last section, the fumes are expelled
through a vertical section.
Extensions and elbows can be added to ex-
tend the kit's length.
The chart of Fig. 6.12 gives the allowable di-
mensions of the ducts "a" and "b" of Fig. 6.11.
Each additional elbow reduces the overall ac-
ceptable length of the flue system as follows:
45° (60/100 mm) reduce length by 0,5 m.
90° (60/100 mm) reduce length by 1 m.
45° (60 mm) reduce length by 0,65 m.
90° (60 mm) reduce length by 0,85 m.
- 36 -
INSTALLATION
90° =--- 1 m
ø 60/100 mm
45° =--- 0,5 m
"a" vertical length (m)
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
Allowed values
0.6
0.4
0.2
0.0
0.4
0.6
0.8
1.0
Fig. 6.12
6.9

Electrical connections

Connection to the electricity supply
• Remove the front panel of the case (see
the section "Dismantling the external pan-
els" to page 50).
• Remove the screws I and J (Fig. 6.13).
J
K
Fig. 6.13
• Loosen the screws K.
• Remove the side panels or move the low-
1.2
1.4
1.6
1.8
"b" horizontal length (m)
I
J