7
Cannot Receive Data from Parallel Interface.
•
Is "PARALLEL I/F" (in menu 1) set to "ENABLE"?
No
Set the "PARALLEL I/F" (in menu 1) to "ENABLE."
•
Yes
Is Parallel interface of the host computer set to "Bidirectional Communication"?
Yes Set the "Bidirectional Communication" of "Parallel Interface" (in menu 2) to "ENABLE."
•
No
Set the "Bidirectional Communication" of "Parallel Interface" (in menu 2) to "DISABLE."
•
Is Data printed out?
Yes End
•
No
Is Parallel interface cable connected correctly?
No
Connect the cable correctly.
•
Yes
Check the connection of the parallel interface cable (for wire disconnections or bent pins).
Is it recovered?
No
Replace the parallel interface cable.
•
Yes
Replace the main board (PCE PCB) or check hardware and software of the host computer.