Examine the area surrounding the repaired location for damage or deterioration. Observe that screws, parts and wires have
been returned to original positions. Afterwards, perform the following tests and confirm the specified values in order to ver-
ify compliance with safety standards.
1. Insulation resistance test
Confirm the specified insulation resistance or greater between power cord plug prongs and externally exposed parts of
the set (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, earphone jacks,
etc.). See table below.
2. Dielectric strength test.
Confirm specified dielectric or strength or greater between power cord plug prongs and exposed accessible parts of the
set(RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, earphone jacks,
etc.) See table below.
3. Clearance distance
When replacing primary circuit components, confirm spec-
ified clearance distance (d), (d") between soldered termi-
nals, and between terminals and surrounding metallic
parts. see table below.
Table 1 : Rating for selected areas
AC Line Voltage
100V
110 to 130V
* 100 to 250V
Note : This table is unofficial and for reference only. Be sure to confirm the precise values for your particular country and
locality.
4. Leakage current test
Confirm specified or lower leakage current between B (earth ground, power cord plug prongs) and externally exposed
accessible parts (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, ear-
phone jacks, etc.)
Measuring Method : (Power ON)
Insert load Z between B (earth ground, power cord plug
prongs) and exposed accessible parts. Use an AC volt-
meter to measure across both terminals of load Z.
See figure and following table:
Table 2 : Leakage current ratings for selected areas
AC Line Voltage
100V
110 to 130 V
100 to 130 V
200 to 250 V
Note : This table is unofficial and for reference only. Be sure to confirm the precise values for your particular country and
locality.
Region
Japan
USA & Canada
South America
Region
Load Z
Japan
1.5kµF
USA & Canada
South America
Insulation
Resistance
≥1MΩ500 V DC
---
≥10 MΩ/500 V DC
Fig. 2
Leakage Current (i)
i ≤ 1mA rms
1kΩ
i ≤ 0.5 mA rms
1.5kΩ
i ≤ 0.7 mA peak
i ≤ 2mA dc
2kΩ
i ≤ 0.7 mA peak
i ≤ 2mA dc
50kΩ
2
Dielectric
Strength
Distance (d), (d')
1kV 1 minute
900V 1 minute
4 kV 1 minute
(z:Power cord)
Earth Ground
(B) to :
Exposed accessible parts
Exposed accessible parts
Antenna earth terminals
Other terminals
Fig. 1
Clearance
≥3 mm
≥3.2mm
≥6mm(d)
≥8mm(d')