Mains Electricity Connection - CDA HVN61 Manual For Installation, Use And Maintenance

Hide thumbs Also See for HVN61:
Table of Contents

Advertisement

Mains Electricity Connection

Warning! this appliance must be earthed
We recommend that the appliance is connected by a qualified
electrician, who is a member of the N.I.C.E.I.C. and who will comply
with the I.E.E. and local regulations.
This appliance is intended to be connected to fixed wiring and is not
suitable for connection to a 13a plug or 13a supply.
This appliance is intended to be connected to fixed wiring by a
double pole switch, having a contact separation of at least 3mm in
all poles. The switch must be positioned no further than 2m from the
appliance.
This appliance is supplied with a 3 core mains cable; the wires are in
accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
Please note:
• The mains cable must only be replaced by a qualified service
engineer and must be of equivalent or better rating (i.e. 2.5mm 2 ,
HO5V2V2-F).
• This appliance is intended to be connected to the mains supply with
a cable of cross section area 2.5 mm2. A larger cable will not fit the
terminal connections.