Connecting Lp Cylinder And Hose / Regulator To Grill - BRINKMAN Vertex Sear Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

Note: If burner does not light or flame is too low, you may have spider or other insect blockage in burner, or
the flow limiting device has been activated. See "Burner Assembly/Maintenance" under Proper Care
and Maintenance, or "Regulator Resetting Procedure" under Connecting LP Cylinder and
Hose/Regulator to Grill.
LIGHTING THE SIDE BURNER:
1. Slide to open lid before lighting side burner.
2. Make sure control knob is in the "OFF" position.
3. Push and turn side burner control knob to the "HIGH" position.
4. Press the electronic igniter on the main control panel and hold for
3–5 seconds to light burner.
5. If ignition does NOT occur in 5 seconds, turn control knob to
"OFF", wait 5 minutes to allow gas to dissipate and repeat
lighting procedure.
6. If burner does not ignite using the push-button igniter,
wait 5 minutes, see "Match Lighting the Side Burner" section.
7. To turn off, turn control knob clockwise until it locks in the
"OFF" position.
MATCH LIGHTING THE SIDE BURNER:
1. Slide to open lid before lighting side burner.
2. Turn the burner control knob to "OFF".
3. Strike and carefully place a match approximately
1/2" (1 to 2 cm) from the burner.
4. Turn the side burner control knob to the "HIGH" position.
The burner should light within 5 seconds.
5. If the burner does not light, turn the control knob to "OFF" and wait 5 minutes for gas to dissipate and
repeat lighting procedure.
6. If the burner does not light within the first few attempts of match lighting, there is a problem with the gas
supply. Turn off the gas at the burner and cylinder. DO NOT attempt to operate the grill until the problem
is found and corrected. See "Trouble Shooting" section of this manual.
Note: If burner does not light or flame is too low, you may have spider or other insect blockage in
burner, or the flow limiting device has been activated. See "Burner Assembly/Maintenance" under
Proper Care and Maintenance, or "Regulator Resetting Procedure" under Connecting LP Cylinder
and Hose/Regulator to Grill.
Note: Vertex Sear Burner must be "OFF" to use the two lower burners. The two burners under the
Vertex Sear Burner will not turn ON when the Vertex Sear Burner is in the "ON" position.
WARNING! Make sure all knobs are in the "OFF" position to prevent gas from flowing.
LIGHTING THE VERTEX SEAR BURNER:
1. Open lid before lighting Vertex Sear burner.
2. Make sure Vertex Sear burner control knob is in the
"OFF" position.
3. Push and turn the Vertex Sear burner control knob
to the "ON" position.
4. Press the electronic igniter and hold for 3 – 5 seconds
to light burner.
5. If ignition does NOT occur in 5 seconds, turn control knob to "OFF",
wait 5 minutes to allow gas to dissipate and repeat lighting procedure.
6. If burner does not ignite using the push-button igniter, wait 5 minutes,
see "Match Lighting the Vertex Sear Burner" section.
7. To turn off, turn control knob clockwise until it locks in the "OFF"
position. This does not turn off the gas flow from the cylinder.
11
Matchlighter
OFF

Advertisement

Chapters

Table of Contents
loading