Rinnai Arriva Operation And Installation Manual page 33

Hide thumbs Also See for Arriva:
Table of Contents

Advertisement

Arriva Installation
Heater body
Carefully move appliance body into enclosure cavity ensuring both the gas
installation
pipe and flue transition are aligned with their access openings.
As the appliance is pushed into place ensure the flexible gas connection
coils freely inside the appliance and that the gas pipe penetrates through
the centre of the gas access point.
Securing the
Once the heater is in position open the air return louvre doors to gain
heater body
access to the appliance mounting points. There are 4 in total, 2 upper and 2
lower on each side of the appliance.
Secure the heater body through these points using appropriate fixings.
Flue spigot and
The Rinnai Arriva flueing system must be installed in accordance with the
air inlet hose
instructions supplied.
Once the flue and air connections are secured slide the flue access panel
Flue access
back into position and fasten.
panel
The hole in the flue access panel is offset and can be reversed to align with
the final position of the flue connections.
Fitting
Slide the upper elbow onto the horizontal flue pipe. Slide the vertical flue
final flue
pipe up and into the upper elbow and fix together using the clamp.
connections
Check all connections are properly engaged and are inserted beyond the
O-ring seal.
rinnai new Zealand Limited
Mounting
points
Arriva Operation and Installation Manual: 10343-E
33
05-10