Auto Repeater Function (Usa Version Only); Repeater Operation - Icom IC-V8 Instruction Manual

Icom marine radio user manual
Hide thumbs Also See for IC-V8:
Table of Contents

Advertisement

Auto repeater
function
The USA version automatically activates the repeater settings (du-
plex, ON/OFF, duplex direction, tone encoder ON/OFF) when the
operating frequency falls within or outside of the general repeater
output frequency range. The offset and repeater tone frequencies
are not changed by the auto repeater function, reset these fre-
quencies, if necessary.
q
While pushing [Y]+[Z], turn the power ON to enter
.
MODE
w
Push [Y]/[Z] several times until
"RPt." appears.
e
Rotate [VOL] to select the desired
condition.
• "OF"—the auto repeater function is
turned OFF;
"R1"—the auto repeater function acti-
vates for duplex only;
"R2"—the auto repeater function acti-
vates for duplex and tone.
r
Push [#•
ENT
.
MODE
Frequency range and offset direction
FREQUENCY RANGE
145.200–145.495 MHz
146.610–146.995 MHz
147.000–147.395 MHz
(USA version only)
] to exit
INITIAL SET

REPEATER OPERATION

INITIAL SET MODE
USING
F
SKIP
AO
MR
SKIP
F
AO
MR
SKIP
F
AO
MR
DUPLEX DIRECTION
"–" appears
"+" appears
5
INITIAL SET
D
TX
75
50
LM
25
D
TX
75
50
LM
25
D
TX
75
50
LM
25
24