■ Auto repeater function
(USA version only)
The USA version automatically activates the repeater settings
(duplex, ON/OFF, duplex direction, tone encoder ON/OFF)
when the operating frequency falls within or outside of the
general repeater output frequency range. The offset and re-
peater tone frequencies are not changed by the auto repeater
function. Reset these frequencies, if necessary.
q While pushing [Y Y ] and [Z Z ], turn the power ON to enter
.
TIAL SET MODE
w Push [Y Y ] or [Z Z ] several times until "RPt" appears.
e Rotate [VOL] to select the desired condition.
• "OF"— the auto repeater function is turned OFF;
• "R1"— the auto repeater function activates for duplex only;
• "R2"— the auto repeater function activates for duplex and tone.
r Push [✱•
] (or [D•
ENT
CLR
• Frequency range and offset direction
Frequency range
145.200–145.495 MHz
146.610–146.995 MHz
147.000–147.395 MHz
INITIAL SET MODE
USING
INI
]) to exit
.
INITIAL SET MODE
Duplex direction
"–" appears
"+" appears

■ Repeater lockout

This function helps prevent interference to other stations by
inhibiting your transmission when a signal is received. The
transceiver has two inhibiting conditions, repeater and busy.
q While pushing [Y Y ] and [Z Z ], turn the power ON to enter
.
TIAL SET MODE
w Push [Y Y ] or [Z Z ] several times until "RLO" appears.
e Rotate [VOL] to turn the repeater lockout function to "RP,"
-
"bU" or OFF.
• "RP": Transmit is inhibited when a signal with un-matched sub-
audible tone is received.
• "bU": Transmit is inhibited when a signal is received.
r Push [✱•
] (or [D•
ENT
REPEATER OPERATION
INITIAL SET MODE
USING
]) to exit
CLR
INITIAL SET MODE
5
5
-
INI
.
19

Advertisement

Table of Contents
loading